Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/295451
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Iridium nanoclusters as high sensitive-tunable elemental labels for immunoassays: Determination of IgE and APOE in aqueous humor by inductively coupled plasma-mass spectrometry

AutorMenero-Valdés, Paula; Lores-Padín, Ana; Fernández-Vega, Beatriz; González-Iglesias, Héctor CSIC ORCID ; Pereiro, Rosario
Palabras claveIridium nanoclusters
Metal-labelled immunoprobe
Elemental mass spectrometry
Immunoglobulin E
APOE
Primary open angle glaucoma
Fecha de publicación1-jul-2022
EditorElsevier BV
CitaciónTalanta 244: 123424 (2022)
ResumenIridium nanoclusters (IrNCs) stabilized with citrate were synthesized and then the ligand was exchanged by lipoic acid (LA). The IrNCs@LA were bioconjugated through carbodiimide chemistry with specific antibodies to prepare IrNCs-labelled immunoprobes. The IrNCs-immunoprobes were employed in competitive immunoassays for immunoglobulin E (IgE) and apolipoprotein E (APOE) determination by detecting the iridium through inductively coupled plasma – mass spectrometry (ICP-MS). The IrNCs@LA have a 1.89 nm diameter at average and each NC contains 250 Ir atoms. Labelling of specific antibodies with IrNCs was optimized in terms of recognition capabilities and signal amplification by ICP-MS. Amplification and detection limits can be tuned by selecting the IrNCs:Ab molar ratio. An immunoprobe prepared by mixing a 10:1 IrNC:Ab molar ratio was selected for the determination of IgE and APOE in aqueous humor, achieving a signal amplification of 1760 iridium atoms per molecule of the sought protein and limits of detection in the tens of pg mL of protein. The IrNCs-immunoprobes were evaluated for IgE determination in serum samples as well as for IgE and APOE in aqueous humor (from controls subjects and patients affected by primary open angle glaucoma) by ICP-MS, being required just sample dilution as pre-treatment. Results were corroborated with commercial ELISA kits.
Versión del editorhttp://dx.doi.org/10.1016/j.talanta.2022.123424
URIhttp://hdl.handle.net/10261/295451
DOI10.1016/j.talanta.2022.123424
Identificadoresdoi: 10.1016/j.talanta.2022.123424
issn: 0039-9140
e-issn: 1873-3573
Aparece en las colecciones: (IPLA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Iridium nanoclusters_Menero.pdf2,52 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

9
checked on 28-abr-2024

WEB OF SCIENCETM
Citations

5
checked on 27-feb-2024

Page view(s)

39
checked on 15-may-2024

Download(s)

33
checked on 15-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons