Ion-induced bias in Ag2S luminescent nanothermometers

AutorParís Ogáyar, Marina; Méndez-González, Diego; Zabala Gutiérrez, Irene; Artiga, Álvaro; Rubio-Retama, Jorge; Calderón, Óscar G.; Melle, Sonia; Serrano Rubio, Aída CSIC ORCID ; Espinosa, Ana CSIC ORCID; Jaque, Daniel; Marin, Riccardo
Fecha de publicación19-oct-2023
EditorRoyal Society of Chemistry (UK)
CitaciónNanoscale 2023,15, 17956-17962
Resumen[EN] Luminescence nanothermometry allows measuring temperature remotely and in a minimally invasive way by using the luminescence signal provided by nanosized materials. This technology has allowed, for example, the determination of intracellular temperature and in vivo monitoring of thermal processes in animal models. However, in the biomedical context, this sensing technology is crippled by the presence of bias (cross-sensitivity) that reduces the reliability of the thermal readout. Bias occurs when the impact of environmental conditions different from temperature also modifies the luminescence of the nanothermometers. Several sources that cause loss of reliability have been identified, mostly related to spectral distortions due to interaction between photons and biological tissues. In this work, we unveil an unexpected source of bias induced by metal ions. Specifically, we demonstrate that the reliability of Ag2S nanothermometers is compromised during the monitoring of photothermal processes produced by iron oxide nanoparticles. The observed bias occurs due to the heat-induced release of iron ions, which interact with the surface of the Ag2S nanothermometers, enhancing their emission. The results herein reported raise a warning to the community working on luminescence nanothermometry, since they reveal that the possible sources of bias in complex biological environments, rich in molecules and ions, are more numerous than previously expected.
Versión del editorhttps://doi.org/10.1039/D3NR03728B
URIhttp://hdl.handle.net/10261/350005
DOI10.1039/D3NR03728B
ISSN2040-3364
E-ISSN2040-3372
Aparece en las colecciones: (ICV) Artículos
(ICMM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
d3nr03728b.pdfArtículo principal1,12 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

22
checked on 26-abr-2024

Download(s)

10
checked on 26-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons