Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/295602
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Real matrix-matched standards for quantitative bioimaging of cytosolic proteins in individual cells using metal nanoclusters as immunoprobes-label: A case study using laser ablation ICP-MS detection

AutorLores-Padín, Ana; Fernández, Beatriz; García, Montserrat; González-Iglesias, Héctor CSIC ORCID ; Pereiro, Rosario
Palabras claveLaser ablation ICP-MS
Matrix-matched calibration
Quantitative imaging of proteins
Metal nanoclusters
Cytosolic proteins
Fecha de publicación15-ago-2022
EditorElsevier BV
CitaciónAnalytica Chimica Acta 1221: 340128 (2022)
ResumenThe persistent lack of adequate matrix-matched reference materials still hinders the quantitative analysis of elements and biomolecules in biological samples by LA-ICP-MS. This fact is especially critical in cell cultures due to their complex matrix. In this work, we propose a novel matrix-matched calibration strategy, which fully mimics the matrix of cultured cells, by using the same cell line of the sample to create laboratory standards. As a model case, the quantitative imaging of two cytosolic proteins (MT2A and APOE) in individual HRPEsv cells was performed by LA-ICP-MS, both in cells subjected to inflammation with cytokine Interleukin-1α (IL-1α) and controls (CT). A single biomarker strategy using Au nanoclusters (AuNCs) as specific antibody labels was employed for the analysis of the selected proteins in individual cells by LA-ICP-MS. HRPEsv cells supplemented with suspensions containing nude AuNCs was employed to generate single-cell laboratory standards (HRPEsv cells@AuNCs). The preparation and characterization of the single-cell laboratory standards by both ICP-MS and LA-ICP-MS were optimized as well as the data treatment protocol required for obtaining the quantitative distribution of the proteins in individual cells. The mass of APOE and MT2A per cell in CT and IL1α−treated HRPEsv cells analysed by LA-ICP-MS using the proposed matrix-matched calibration were successfully corroborated with commercial ELISA kits. In addition, quantitative real time polymerase chain reaction (qPCR) analyses were performed to study the proteins gene expression.
Versión del editorhttp://dx.doi.org/10.1016/j.aca.2022.340128
URIhttp://hdl.handle.net/10261/295602
DOI10.1016/j.aca.2022.340128
Identificadoresdoi: 10.1016/j.aca.2022.340128
issn: 0003-2670
Aparece en las colecciones: (IPLA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Real matrix-matched standards_Lores.pdf4,4 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

6
checked on 16-abr-2024

WEB OF SCIENCETM
Citations

6
checked on 26-feb-2024

Page view(s)

47
checked on 01-may-2024

Download(s)

48
checked on 01-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons