Título

The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation

AutorCeballos, María Teresa CSIC ORCID ; Cardiel, Nicolás; Cobo, Beatriz CSIC ORCID ; Smith, Stephen J.; Witthoeft, Michael C.; Peille, Philippe; Durkin, Malcolm S.
Palabras claveAthena: the advanced telescope for high energy astrophysics
X-IFU: The X-ray Integral Field Unit
Space instrumentation
X-rays
Observatory
Astrophysics
Instrumentation and Methods for Astrophysics
Fecha de publicación21-mar-2024
EditorSpringer Nature
CitaciónExperimental Astronomy
ResumenThe X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy res- olution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detec- tors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instru- mental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
Versión del editorhttps://doi.org/10.1007/s10686-024-09930-2
URIhttp://hdl.handle.net/10261/351412
DOI10.1007/s10686-024-09930-2
Aparece en las colecciones: (IFCA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Ceballos_et_al-2024-Experimental_Astronomy.pdfMain article9,8 MBAdobe PDFVisualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

14
checked on 27-abr-2024

Download(s)

2
checked on 27-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.