Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/347395
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

An updated measurement of the Hubble constant from near-infrared observations of Type Ia supernovae

AutorGalbany, Lluís CSIC ORCID ; Jaeger, T. de; Riess, Adam; Müller-Bravo, Tomás E. CSIC ORCID; Dhawan, Suhail; Phan, Kim; Stritzinger, Maximilian; Karamehmetoglu, Emir; Leibundgut, Bruno; Burns, Christopher R.; Peterson, Erik; D'Arcy Kenworthy, W.; Johansson, Joel; Maguire, Kate; Jha, Saurabh W.
Palabras claveSupernovae: general
Galaxies: distances and redshifts
Cosmological parameters
Fecha de publicación2023
EditorEDP Sciences
CitaciónAstronomy and Astrophysics 679: A95 (2023)
ResumenWe present a measurement of the Hubble constant (H0) using type Ia supernovae (SNe Ia) in the near-infrared (NIR) from the recently updated sample of SNe Ia in nearby galaxies with distances measured via Cepheid period-luminosity relations by the SH0ES project. We collected public near-infrared photometry of up to 19 calibrator SNe Ia and 57 SNe Ia in the Hubble flow (z > 0.01), and directly measured their peak magnitudes in the J- and H-band by Gaussian processes and spline interpolation. Calibrator peak magnitudes together with Cepheid-based distances were used to estimate the average absolute magnitude in each band, while Hubble-flow SNe were used to constrain the zero-point intercept of the magnitude–redshift relation. Our baseline result of H0 is 72.3 ± 1.4 (stat) ±1.4 (syst) km s−1 Mpc−1 in the J-band and 72.3 ± 1.3 (stat) ±1.4 (syst) km s−1 Mpc−1 in the H-band, where the systematic uncertainties include the standard deviation of up to 21 variations of the analysis, the 0.7% distance scale systematic from SH0ES Cepheid anchors, a photometric zero-point systematic, and a cosmic variance systematic. Our final measurement represents a measurement with a precision of 2.8% in both bands. Among all the analysis variants, the largest change in H0 comes from limiting the sample to those SNe from the CSP and CfA programs; they are noteworthy because they are the best calibrated, yielding H0 ∼ 75 km s−1 Mpc−1 in both bands. We explore applying stretch and reddening corrections to standardize SN Ia NIR peak magnitudes, and we demonstrate that they are still useful to reduce the absolute magnitude scatter and, which improves its standardization, at least up to the H-band. Based on our results, in order to improve the precision of the H0 measurement with SNe Ia in the NIR in the future, we would need to increase the number of calibrator SNe Ia, to be able to extend the Hubble–Lemaître diagram to higher redshift, and to include standardization procedures to help reduce the NIR intrinsic scatter.
Versión del editorhttps://doi.org/10.1051/0004-6361/202244893
URIhttp://hdl.handle.net/10261/347395
DOI10.1051/0004-6361/202244893
E-ISSN1432-0746
Aparece en las colecciones: (ICE) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
anupdatesupernovae.pdf3,89 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

4
checked on 23-may-2024

Page view(s)

24
checked on 28-may-2024

Download(s)

4
checked on 28-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons