Methodology adjusting for least squares regression slope in the application of multiplicative scatter correction to near-infrared spectra of forage feed simples

AutorDhanoa, M.S.; López, Secundino CSIC ORCID; Sanderson, R.; Lister, S.J.; Barnes, R.J.; Ellis, J.L.; France, J.
Palabras claveErrors-in-variables
Measurement error models
Multiplicative signal correction
Near-infrared spectroscopy
Slope attenuation
Type II regression
Fecha de publicación2023
EditorJohn Wiley & Sons
CitaciónJournal of Chemometrics: e3511 (2023)
ResumenScatter corrections are commonly applied to refine near-infrared (NIR) spectra. The aim of this study is to assess the impact of measurement errors when using ordinary least squares (OLS) for multiplicative scatter correction (MSC). Any measurement errors attached to the set-mean spectrum may attenuate the OLS slope and that in turn will affect the estimate of the intercept and the adjustment of the spectra when using MSC methods to mitigate scattering. A corrected least squares slope may be used instead to prevent this problem, although the impact of this approach on the final outcome will depend on the relative size of the measurement errors in the individual spectra and the set-mean spectrum. The errors-in-variables or type II regression model (also known as Deming regression) and its special cases, major axis (MA) and reduced major axis (RMA), are discussed and illustrated. The extent of OLS slope bias or attenuation is demonstrated as is the resulting MSC spectral distortion. Further modification to the MSC transformation method is also suggested. The influence of scattering correction (by MSC, standard normal variate (SNV) and detrending) and of using the maximum likelihood estimate of the slope for MSC on the prediction of chemical composition of Lucerne herbage from NIR spectra was assessed. The predictive performance was slightly improved by the use of scattering corrections with fairly minor differences among methods. Nonetheless, it seems well worth considering the use of type II regression models for assessing MSC application aiming at improving the goodness of prediction from NIR spectra.
Descripción20 páginas, 7 figuras, 5 tablas.
Versión del editorhttps://doi.org/10.1002/cem.3511
URIhttp://hdl.handle.net/10261/336006
E-ISSN1099-128X
Aparece en las colecciones: (IGM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Journal of Chemometrics - 2023 - Dhanoa.pdfArtículo principal3,04 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

41
checked on 27-abr-2024

Download(s)

6
checked on 27-abr-2024

Google ScholarTM

Check


Este item está licenciado bajo una Licencia Creative Commons Creative Commons