Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/221756
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Spark ablation as sampling device for inductively coupled plasma mass spectrometric analysis of low-alloyed steels

AutorGómez Coedo, Aurora CSIC ; Dorado López, María Teresa CSIC ; Fernández, B. CSIC ORCID
Palabras claveSpark ablation
Inductively coupled plasma mass spectrometry
Low-alloyed steels analysis
Fecha de publicación1995
EditorRoyal Society of Chemistry (UK)
CitaciónJournal of Analytical Atomic Spectrometry 10: 859- 863 (1995)
ResumenA method for the direct elemental analysis of low-alloyed steels is described. Spark ablation coupled with excitation in a 1.5 kW argon inductively coupled plasma was applied to the direct determination of Mn, Si, P, Al, B, Co, Nb, V, Zr and Sb in low-alloyed steels by mass spectrometry. For aerosol production, a medium-voltage spark at a high repetition rate (500 V, 400 Hz) was used. A cyclone device was designed to control the aerosol particle size; with this system the total amount of material reaching the plasma is low (about 4 μg min -1) and a more uniform particle size distribution is achieved, thereby improving the precision of the measurements and preventing deposition of material in the torch injector and sampling cone. Particles re-collected downstream of the cyclone device were mostly spherical in shape, with a particle diameter of less than 1.0 μm. When using optimized operating parameters, and a low abundance iron isotope (58Fe) as an internal standard, relative standard deviations at concentration levels of ten times the detection limit were below 2.5%. Detection limits (3s) for Nb, V, Zr, Mn, Co, Al and Sb ranged from 0.08 to 0.32 μg g-1; for Si, B and P, detection limits were 1.5, 2.1 and 2.5 μg g-1, respectively. These values are comparable to those obtained for continuous-flow sample aspiration of a 0.05% m/v Fe matrix solution. The technique was applied to the analysis of the Bureau of Analysed Samples certified reference materials SS-456/1 to SS-460/1, carbon steels (residual series).
Versión del editorhttp://dx.doi.org/10.1039/JA9951000859
URIhttp://hdl.handle.net/10261/221756
DOI10.1039/JA9951000859
Identificadoresdoi: 10.1039/JA9951000859
issn:: 0267-9477
Aparece en las colecciones: (CENIM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Spark_Ablation.pdf874,77 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

WEB OF SCIENCETM
Citations

12
checked on 25-feb-2024

Page view(s)

81
checked on 30-abr-2024

Download(s)

171
checked on 30-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons