Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/290553
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

A comparative study of the Gene‐Trak Listeria assay, the Listeria‐Tek ELISA test and the FDA method for the detection of Listeria species in raw milk

AutorRodríguez, J. L.; Gaya Sicilia, María Pilar; Medina, Milagros CSIC ORCID; Núñez Gutiérrez, Manuel
Fecha de publicación1993
EditorJohn Wiley & Sons
CitaciónLetters in Applied Microbiology 17(4): 178 - 181 (1993)
ResumenA total of 110 raw milk samples were analysed using the Gene‐Trak Listeria assay, unmodified and with four modifications to its enrichment procedure, the Listeria‐Tek ELISA test and the FDA method. Thirty‐five samples yielded confirmed positive results by at least one of the methods tested. The original Gene‐Trak protocol yielded 24 confirmed positive results, significantly higher than the 13 obtained with the Listeria‐Tek ELISA test or with the FDA method. The modifications to the Gene‐Trak Listeria assay did not significantly increase the detection rate of Listeria spp. Copyright © 1993, Wiley Blackwell. All rights reserved
URIhttp://hdl.handle.net/10261/290553
DOI10.1111/j.1472-765X.1993.tb00389.x
ISSN0266-8254
E-ISSN1472-765X
Aparece en las colecciones: (INIA) Artículos

Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

9
checked on 18-may-2024

WEB OF SCIENCETM
Citations

11
checked on 24-feb-2024

Page view(s)

18
checked on 21-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.