Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/248554
COMPARTIR / EXPORTAR:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”

AutorBenedi, Clara CSIC ORCID CVN; Viñas, María CSIC ORCID; Lago, Carmen M.; Aissati, Sara CSIC; Castro, Alberto de CSIC ORCID; Dorronsoro, Carlos CSIC ORCID; Marcos, Susana CSIC ORCID
Palabras claveVisual acuity
Aberrations
Magnification
Adaptive optics
Cuvette
Fecha de publicación20-ago-2021
EditorDIGITAL.CSIC
CitaciónBenedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana; 2021; Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”; DIGITAL.CSIC; http://dx.doi.org/10.20350/digitalCSIC/13974
ResumenVisual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus).
DescripciónThe provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021).
URIhttp://hdl.handle.net/10261/248554
DOI10.20350/digitalCSIC/13974
ReferenciasBenedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana (2021). Optical and visual quality of real intraocular lenses physically projected on the patient’s eye. Biomedical Optics Express 12(10): 6360-6374. https://doi.org/10.1364/BOE.432578 . http://hdl.handle.net/10261/250758
Aparece en las colecciones: (CFMAC-IO) Conjuntos de datos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
All_data_cuvette.xlsxdataset25,09 kBMicrosoft Excel XMLVisualizar/Abrir
readme.odt5,66 kBOpenDocument TextVisualizar/Abrir
Mostrar el registro completo

CORE Recommender
fair
fair eva

Page view(s)

143
checked on 07-may-2024

Download(s)

36
checked on 07-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.