Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/248554
COMPARTIR / EXPORTAR:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorBenedi, Claraes_ES
dc.contributor.authorViñas, Maríaes_ES
dc.contributor.authorLago, Carmen M.es_ES
dc.contributor.authorAissati, Saraes_ES
dc.contributor.authorCastro, Alberto dees_ES
dc.contributor.authorDorronsoro, Carloses_ES
dc.contributor.authorMarcos, Susanaes_ES
dc.date.accessioned2021-08-23T08:44:17Z-
dc.date.available2021-08-23T08:44:17Z-
dc.date.issued2021-08-20-
dc.identifier.citationBenedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana; 2021; Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”; DIGITAL.CSIC; http://dx.doi.org/10.20350/digitalCSIC/13974-
dc.identifier.urihttp://hdl.handle.net/10261/248554-
dc.descriptionThe provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021).-
dc.description.abstractVisual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus).es_ES
dc.description.sponsorshipSpanish Government FIS2017-84753R. Spanish Government Predoctoral Grant FPU16/01944 to SA. ERC AdG-2018-833106 SILKEYE to SM.es_ES
dc.language.isoenges_ES
dc.publisherDIGITAL.CSIC-
dc.relationinfo:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/FIS2017-84753Res_ES
dc.relationinfo:eu-repo/grantAgreement/EC/H2020/833106es_ES
dc.relation.isreferencedbyBenedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana (2021). Optical and visual quality of real intraocular lenses physically projected on the patient’s eye. Biomedical Optics Express 12(10): 6360-6374. https://doi.org/10.1364/BOE.432578 . http://hdl.handle.net/10261/250758-
dc.rightsopenAccesses_ES
dc.subjectVisual acuity-
dc.subjectAberrations-
dc.subjectMagnification-
dc.subjectAdaptive optics-
dc.subjectCuvette-
dc.titleData for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”es_ES
dc.typedatasetes_ES
dc.identifier.doi10.20350/digitalCSIC/13974-
dc.description.peerreviewedPeer reviewedes_ES
dc.contributor.funderEuropean Commissiones_ES
dc.contributor.funderMinisterio de Economía y Competitividad (España)es_ES
dc.relation.csices_ES
oprm.item.hasRevisionno ko 0 false*
dc.identifier.funderhttp://dx.doi.org/10.13039/501100000780es_ES
dc.identifier.funderhttp://dx.doi.org/10.13039/501100003329es_ES
dc.contributor.orcidBenedi, Clara [0000-0002-9361-4137]es_ES
dc.contributor.orcidViñas, Maria [0000-0003-1296-9508]es_ES
dc.contributor.orcidCastro, Alberto de [0000-0002-2873-3412]es_ES
dc.contributor.orcidAissati, Sara [0000-0003-0254-1946]es_ES
dc.contributor.orcidDorronsoro, Carlos [0000-0001-5968-1128]es_ES
dc.contributor.orcidMarcos, Susana [0000-0001-5511-1697]es_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_ddb1es_ES
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_ddb1-
item.fulltextWith Fulltext-
item.cerifentitytypeProducts-
item.languageiso639-1en-
item.openairetypedataset-
Aparece en las colecciones: (CFMAC-IO) Conjuntos de datos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
All_data_cuvette.xlsxdataset25,09 kBMicrosoft Excel XMLVisualizar/Abrir
readme.odt5,66 kBOpenDocument TextVisualizar/Abrir
Show simple item record

CORE Recommender
fair
fair eva

Page view(s)

144
checked on 27-may-2024

Download(s)

37
checked on 27-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.