Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/248554
COMPARTIR / EXPORTAR:
SHARE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Benedi, Clara | es_ES |
dc.contributor.author | Viñas, María | es_ES |
dc.contributor.author | Lago, Carmen M. | es_ES |
dc.contributor.author | Aissati, Sara | es_ES |
dc.contributor.author | Castro, Alberto de | es_ES |
dc.contributor.author | Dorronsoro, Carlos | es_ES |
dc.contributor.author | Marcos, Susana | es_ES |
dc.date.accessioned | 2021-08-23T08:44:17Z | - |
dc.date.available | 2021-08-23T08:44:17Z | - |
dc.date.issued | 2021-08-20 | - |
dc.identifier.citation | Benedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana; 2021; Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”; DIGITAL.CSIC; http://dx.doi.org/10.20350/digitalCSIC/13974 | - |
dc.identifier.uri | http://hdl.handle.net/10261/248554 | - |
dc.description | The provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021). | - |
dc.description.abstract | Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus). | es_ES |
dc.description.sponsorship | Spanish Government FIS2017-84753R. Spanish Government Predoctoral Grant FPU16/01944 to SA. ERC AdG-2018-833106 SILKEYE to SM. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | DIGITAL.CSIC | - |
dc.relation | info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/FIS2017-84753R | es_ES |
dc.relation | info:eu-repo/grantAgreement/EC/H2020/833106 | es_ES |
dc.relation.isreferencedby | Benedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana (2021). Optical and visual quality of real intraocular lenses physically projected on the patient’s eye. Biomedical Optics Express 12(10): 6360-6374. https://doi.org/10.1364/BOE.432578 . http://hdl.handle.net/10261/250758 | - |
dc.rights | openAccess | es_ES |
dc.subject | Visual acuity | - |
dc.subject | Aberrations | - |
dc.subject | Magnification | - |
dc.subject | Adaptive optics | - |
dc.subject | Cuvette | - |
dc.title | Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye” | es_ES |
dc.type | dataset | es_ES |
dc.identifier.doi | 10.20350/digitalCSIC/13974 | - |
dc.description.peerreviewed | Peer reviewed | es_ES |
dc.contributor.funder | European Commission | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad (España) | es_ES |
dc.relation.csic | Sí | es_ES |
oprm.item.hasRevision | no ko 0 false | * |
dc.identifier.funder | http://dx.doi.org/10.13039/501100000780 | es_ES |
dc.identifier.funder | http://dx.doi.org/10.13039/501100003329 | es_ES |
dc.contributor.orcid | Benedi, Clara [0000-0002-9361-4137] | es_ES |
dc.contributor.orcid | Viñas, Maria [0000-0003-1296-9508] | es_ES |
dc.contributor.orcid | Castro, Alberto de [0000-0002-2873-3412] | es_ES |
dc.contributor.orcid | Aissati, Sara [0000-0003-0254-1946] | es_ES |
dc.contributor.orcid | Dorronsoro, Carlos [0000-0001-5968-1128] | es_ES |
dc.contributor.orcid | Marcos, Susana [0000-0001-5511-1697] | es_ES |
dc.type.coar | http://purl.org/coar/resource_type/c_ddb1 | es_ES |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_ddb1 | - |
item.fulltext | With Fulltext | - |
item.cerifentitytype | Products | - |
item.languageiso639-1 | en | - |
item.openairetype | dataset | - |
Aparece en las colecciones: | (CFMAC-IO) Conjuntos de datos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
All_data_cuvette.xlsx | dataset | 25,09 kB | Microsoft Excel XML | Visualizar/Abrir |
readme.odt | 5,66 kB | OpenDocument Text | Visualizar/Abrir |
CORE Recommender
Page view(s)
144
checked on 27-may-2024
Download(s)
37
checked on 27-may-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.