Título

Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital

AutorBellido, Virginia; Freckman, Guido; Pérez, Antonio; Galindo, Rodolfo J.
Fecha de publicaciónnov-2023
EditorElsevier
CitaciónEndocrine Practice 29(11): 919-927 (2023)
ResumenFor years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward.
Versión del editorhttps://doi.org/10.1016/j.eprac.2023.06.007
URIhttp://hdl.handle.net/10261/349238
DOI10.1016/j.eprac.2023.06.007
ISSN1530-891X
E-ISSN1934-2403
Aparece en las colecciones: (IBIS) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf59,24 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

14
checked on 21-may-2024

Download(s)

1
checked on 21-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.