Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/333495
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Recovery of corneal sensitivity to mechanical and chemical stimulation after laser in situ keratomileusis

AutorGallar, Juana CSIC ORCID; Acosta, M. Carmen CSIC ORCID; Moilanen, Jukka A. O.; Holopainen, Juha M.; Belmonte, Carlos CSIC ORCID; Tervo, Timo M. T.
Fecha de publicación2004
EditorSlack Incorporated
CitaciónJournal of Refractive Surgery 20: 229-235 (2004)
Resumen[Purpose]: To evaluate the time course of changes in corneal sensitivity to mechanical and chemical stimuli produced by laser in situ keratomileusis (LASIK) in humans.
[Methods]: We performed a cross-sectional study of 17 LASIK-operated eyes (VisX S2, equipped with version 2.50-3.10 software) and 15 control eyes of 17 individuals to evaluate regeneration of corneal sensitivity after LASIK. Gas pulses of variable flow and compositions were applied to the cornea by a non-contact gas esthesiometer. Mechanical stimuli consisted of air puffs at flows from 0 to 200 ml/min. Chemical stimulation was made with gas pulses containing 0% to 80% CO2 in air at subthreshold flow. Mechanical and chemical thresholds and intensity-response curves for the evoked sensations were determined prior to surgery, and 7 to 9 days, 3 to 5 months, and 1.5 to 2.5 years after surgery.
[Results]: Corneal sensitivity to mechanical stimulation was enhanced 7 to 9 days after surgery but subsequently dropped markedly and remained significantly below control levels 3 to 5 months after LASIK. Sensitivity to both mechanical and chemical types of stimuli was close to normal 2 years postoperatively.
[Conclusions]: Corneal sensitivity decreased immediately after LASIK but mechanical sensitivity showed a transient hyperesthesia 7 to 9 days afterward. Subsequently, a long-lasting and deep hypoesthesia to mechanical and chemical stimuli was observed. Gas esthesiometry revealed that disturbances of corneal sensation still exist at times when coarse mechanical sensitivity appeared to be normal.
Versión del editorhttps://doi.org/10.3928/1081-597X-20040501-06
URIhttp://hdl.handle.net/10261/333495
DOI10.3928/1081-597X-20040501-06
ISSN1081-597X
Aparece en las colecciones: (IN) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf59,24 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

14
checked on 15-may-2024

SCOPUSTM   
Citations

50
checked on 26-may-2024

WEB OF SCIENCETM
Citations

41
checked on 26-feb-2024

Page view(s)

25
checked on 29-may-2024

Download(s)

4
checked on 29-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.