Accuracy study of the Oculus Touch v2 versus inertial sensor for a single-axis rotation simulating the elbow’s range of motion

AutorRojo, Ana; Cortina, J.; Sánchez, C.; Urendes, Eloy José CSIC ORCID; García-Carmona, Rodrigo; Raya, Rafael CSIC ORCID
Palabras claveAccuracy
Elbow
Inertial measurement unit
Range of motion
Rehabilitation
Virtual reality
Fecha de publicación2022
EditorSpringer Nature
CitaciónVIRTUAL REALITY 26: 1651- 1662 (2022)
ResumenVirtual reality (VR) has emerged as a valid addition to conventional therapy in rehabilitation and sports medicine. This has enabled the development of novel and affordable rehabilitation strategies. However, before VR devices can be used in these situations, they must accurately capture the range of motion of the body-segment where they are mounted. This study aims to state the accuracy of the Oculus Touch v2 controller when used to measure the elbow’s motion in the sagittal plane. The controller is benchmarked against an inertial sensor (ENLAZA), which has already been validated as a reliable measurement device. We have developed a virtual environment that matches both the Oculus Touch v2 and the inertial sensor orientations using a digital goniometer. We have also collected the orientation measurements given by each system for a set of 17 static angles that cover the full range of normal elbow flexion and hyperextension motion, in 10° intervals from − 10° (hyperextension) to 150° (flexion). We have applied the intra-rater reliability test to assess the level of agreement between the measurements of these devices, obtaining a value of 0.999, with a 95% confidence interval ranged from 0.996 to 1.000. By analyzing the angle measurement outcomes, we have found that the accuracy degrades at flexion values between 70° and 110°, peaking at 90°. The accuracy of Oculus Touch v2 when used to capture the elbow’s flexion motion is good enough for the development of VR rehabilitation applications based on it. However, the flaws in the accuracy that have been revealed in this experimental study must be considered when designing such applications.
Versión del editorhttp://dx.doi.org/10.1007/s10055-022-00660-4
URIhttp://hdl.handle.net/10261/287749
DOI10.1007/s10055-022-00660-4
Identificadoresdoi: 10.1007/s10055-022-00660-4
issn: 1434-9957
Aparece en las colecciones: (IC) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
s10055-022-00660-4.pdf1,14 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

3
checked on 05-may-2024

WEB OF SCIENCETM
Citations

3
checked on 27-feb-2024

Page view(s)

26
checked on 09-may-2024

Download(s)

44
checked on 09-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons