Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/195079
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Accelerator Mass Spectrometry of 237Np, 239Pu and 240Pu for environmental studies at the Centro Nacional de Aceleradores

AutorLópez-Lora, Mercedes CSIC ORCID; Chamizo, Elena CSIC ORCID
Palabras clave237Np
239,240Pu
AMS non-isotopic normalization
Compact AMS facilities
Environmental studies
He stripper gas
Fecha de publicación15-sep-2019
EditorElsevier
CitaciónNuclear Instruments and Methods in Physics Research - Section B 455: 39-51 (2019)
ResumenLow-energy Accelerator Mass Spectrometry (AMS) systems (i.e. working with 1 MV terminal voltages and below) have demonstrated in the past their capability for the ultra-trace analyses of U and Pu in different field studies. The situation for Np has been different, mostly due to the constraints imposed by the lack of a Np isotopic tracer. Here, it is presented a comprehensive study on the performance of the 1 MV AMS system at the Centro Nacional de Aceleradores (CNA) for: i) the determination of Np using Pu as the AMS normalisation isotope and, ii) the efficient analysis of Pu, Pu and Np when they coexist in the same cathode with traces of natural uranium. Working procedures to analyse Np and Pu on one hand, and Pu on the other, are developed in order to meet competitive U suppression factors and counting efficiencies for every radionuclide. It is demonstrated that the sputtering-process-based temporal trend in the Np/Pu AMS ratios show a coherent behaviour between the different studied matrixes, demonstrating the reliability of the necessary standard correction procedure in AMS. It is proved that Np and Pu concentrations at the 1 fg level and Pu concentrations at the 0.1 fg level can be quantified in samples containing U traces. The technique is applied to the Pu and Np analysis of a seawater reference sample supplied by the International Atomic Energy Agency (IAEA): IAEA-443.
Versión del editorhttp://dx.doi.org/10.1016/j.nimb.2019.06.018
URIhttp://hdl.handle.net/10261/195079
DOI10.1016/j.nimb.2019.06.018
ISSN0168-583X
Aparece en las colecciones: (CNA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,35 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

19
checked on 01-may-2024

WEB OF SCIENCETM
Citations

17
checked on 27-feb-2024

Page view(s)

217
checked on 03-may-2024

Download(s)

25
checked on 03-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.