Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/305272
COMPARTIR / EXPORTAR:
SHARE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Título: | Characterization and Evaluation of Human–Exoskeleton Interaction Dynamics: A Review |
Autor: | Massardi, Stefano CSIC ORCID; Rodríguez-Cianca, David CSIC ORCID ; Pinto-Fernández, David CSIC ORCID; Moreno, Juan Camilo CSIC ORCID ; Lancini, Matteo; Torricelli, Diego CSIC ORCID | Palabras clave: | Exoskeletons wearable robots physical human–exoskeleton interaction Safety forces pressures |
Fecha de publicación: | 2022 | Editor: | Molecular Diversity Preservation International | Citación: | Sensors 22 (2022) | Resumen: | Exoskeletons and exosuits have witnessed unprecedented growth in recent years, especially in the medical and industrial sectors. In order to be successfully integrated into the current society, these devices must comply with several commercialization rules and safety standards. Due to their intrinsic coupling with human limbs, one of the main challenges is to test and prove the quality of physical interaction with humans. However, the study of physical human–exoskeleton interactions (pHEI) has been poorly addressed in the literature. Understanding and identifying the technological ways to assess pHEI is necessary for the future acceptance and large-scale use of these devices. The harmonization of these evaluation processes represents a key factor in building a still missing accepted framework to inform human–device contact safety. In this review, we identify, analyze, and discuss the metrics, testing procedures, and measurement devices used to assess pHEI in the last ten years. Furthermore, we discuss the role of pHEI in safety contact evaluation. We found a very heterogeneous panorama in terms of sensors and testing methods, which are still far from considering realistic conditions and use-cases. We identified the main gaps and drawbacks of current approaches, pointing towards a number of promising research directions. This review aspires to help the wearable robotics community find agreements on interaction quality and safety assessment testing procedures. | Versión del editor: | http://dx.doi.org/10.3390/s22113993 | URI: | http://hdl.handle.net/10261/305272 | DOI: | 10.3390/s22113993 | Identificadores: | doi: 10.3390/s22113993 issn: 1424-8220 |
Aparece en las colecciones: | (IC) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
sensors-22-03993-v4.pdf | 1,71 MB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
Page view(s)
30
checked on 02-may-2024
Download(s)
54
checked on 02-may-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.