Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/296626
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Calibration-based abundances in the interstellar gas of galaxies from slit and IFU spectra

AutorPilyugin, L.S.; Lara-López, M. A.; Vílchez Medina, José Manuel CSIC ORCID; Duarte Puertas, Salvador; Zinchenko, I. A.; Dors, O. L.
Palabras claveISM: abundances
H II regions
Galaxy: abundances
Fecha de publicación28-nov-2022
EditorEDP Sciences
CitaciónAstronomy & Astrophysics 668: A5 (2022)
ResumenIn this work, we make use of available integral field unit (IFU) spectroscopy and slit spectra of several nearby galaxies. The pre-existing empirical R and S calibrations for abundance determinations are constructed using a sample of H II regions with high-quality slit spectra. In this paper, we test the applicability of those calibrations to the IFU spectra. We estimate the calibration-based abundances obtained using both the IFU and the slit spectroscopy for eight nearby galaxies. The median values of the slit and IFU spectra-based abundances in bins of 0.1 in fractional radius Rg (normalised to the optical radius R25) of a galaxy are determined and compared. We find that the IFU and the slit spectra-based abundances obtained through the R calibration are close to each other; the mean value of the differences of abundances is 0.005 dex, and the scatter in the differences is 0.037 dex for 38 datapoints. The S calibration can produce systematically underestimated values of the IFU spectra-based abundances at high metallicities (12 + log(O/H) ≳8.55); the mean value of the differences is −0.059 dex for 21 datapoints, while at lower metallicities the mean value of the differences is −0.018 dex and the scatter is 0.045 dex for 36 data points. This provides evidence that the R calibration produces more consistent abundance estimations between the slit and the IFU spectra than the S calibration. We find that the same calibration can produce close estimations of the abundances using IFU spectra obtained with different spatial resolution and different spatial samplings. This is in line with the recent finding that the contribution of the diffuse ionised gas to the large-aperture spectra of H II regions has a secondary effect. © L. S. Pilyugin et al. 2022.
DescripciónThis is an Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Versión del editorhttp://dx.doi.org/10.1051/0004-6361/202244231
URIhttp://hdl.handle.net/10261/296626
DOI10.1051/0004-6361/202244231
ISSN0004-6361
E-ISSN1432-0746
Aparece en las colecciones: (IAA) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
2022A&A...668A...5P.pdf4,96 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

1
checked on 22-abr-2024

WEB OF SCIENCETM
Citations

2
checked on 21-feb-2024

Page view(s)

26
checked on 29-abr-2024

Download(s)

14
checked on 29-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons