Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/286946
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

First observation of the charge carrier density related gain reduction mechanism in LGADs with the Two Photon Absorption-Transient Current Technique

AutorPape, Sebastian; Currás, Esteban CSIC ORCID ; Fernández-García, Marcos CSIC ORCID ; Moll, Michael; Montero Santos, Raúl; Palomo, Francisco Rogelio; Vila, Iván CSIC ORCID; Wiehe, Moritz; Quintana, Cristian CSIC ORCID
Fecha de publicación2022
EditorElsevier
CitaciónNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1040: 167190 (2022)
ResumenThe Low Gain Avalanche Detector (LGAD) technology is very promising for silicon timing detectors and currently heavily researched. Recent studies show that the gain of LGADs highly depends on the charge carrier density inside the gain layer. To study the charge carrier density related gain reduction, the Two Photon Absorption-Transient Current Technique (TPA-TCT) was employed to obtain information on the drift velocity and electric field of a LGAD for different charge carrier densities. The TPA-TCT uses fs-pulse infrared lasers to provide a three-dimensional resolution to study bulk effects. A compact TPA-TCT setup was developed at CERN and is used to measure current transients against the device depth of a 285μ thick PIN and LGAD, fabricated by IMB-CNM. Methods to extract information about the electric field are employed to verify the charge carrier density related gain reduction. The gain layer of the LGAD is spatially resolved for the first time.
Versión del editorhttps://doi.org/10.1016/j.nima.2022.167190
URIhttp://hdl.handle.net/10261/286946
DOI10.1016/j.nima.2022.167190
ISSN0168-9002
Aparece en las colecciones: (IFCA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
firstechniq.pdf768,41 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

3
checked on 15-may-2024

WEB OF SCIENCETM
Citations

3
checked on 29-feb-2024

Page view(s)

29
checked on 16-may-2024

Download(s)

19
checked on 16-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Este item está licenciado bajo una Licencia Creative Commons Creative Commons