Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/191742
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorRamos, Lourdes-
dc.contributor.authorTabera, Javier-
dc.contributor.authorHernández, Luis M.-
dc.contributor.authorGonzález Carlos, María José-
dc.date.accessioned2019-09-27T09:21:46Z-
dc.date.available2019-09-27T09:21:46Z-
dc.date.issued1998-
dc.identifierdoi: 10.1016/S0003-2670(98)00559-5-
dc.identifierissn: 0003-2670-
dc.identifiere-issn: 1873-4324-
dc.identifier.citationAnalytica Chimica Acta 376(3): 313-323 (1998)-
dc.identifier.urihttp://hdl.handle.net/10261/191742-
dc.description.abstractA simultaneous steam distillation-solvent extraction (SDE) procedure was used for the analysis of polychlorinated biphenyls (PCBs) in dairy products. In spite of the good results previously obtained for the recovery of these pollutants at sub-μg/l levels in spiked water samples, the SDE apparatus did not prove to be an efficient way of extracting endogenous PCBs from dairy products. In an attempt to optimise the simultaneous extraction-clean-up procedure proposed, the different variables affecting the SDE were systematically investigated in depth. These studies have shown that both the extremely low concentration levels of the PCBs in this kind of matrix and the intrinsic complexity of the samples investigated were very important factors affecting the efficiency of SDE for endogenous PCB extraction. Recoveries below 10% were found when different types of dairy products and spiked samples were investigated.-
dc.publisherElsevier-
dc.rightsclosedAccess-
dc.subjectSolid–liquid extraction-
dc.subjectPCBs-
dc.subjectDairy products-
dc.subjectAnalysis-
dc.subjectSDE-
dc.titleSelective extraction of polychlorinated biphenyls from dairy products using steam distillation-solvent extraction at normal pressure-
dc.typeartículo-
dc.identifier.doi10.1016/S0003-2670(98)00559-5-
dc.date.updated2019-09-27T09:21:46Z-
dc.description.versionPeer Reviewed-
dc.language.rfc3066eng-
dc.relation.csic-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.fulltextNo Fulltext-
item.openairetypeartículo-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextnone-
Aparece en las colecciones: (IQOG) Artículos
(IFI) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

10
checked on 30-abr-2024

WEB OF SCIENCETM
Citations

8
checked on 23-feb-2024

Page view(s)

251
checked on 07-may-2024

Download(s)

33
checked on 07-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.