Título

Quantification of signal-to-noise ratio in cerebral cortex recordings using flexible MEAs with co-localized platinum black, carbon nanotubes, and gold electrodes

AutorSuárez Pérez, Alex; Gabriel, Gemma; Rebollo, Beatriz; Illa, Xavi; Guimerà-Brunet, Anton CSIC ORCID; Hernández-Ferrer, Javier CSIC ORCID; Martínez Fernández de Landa, María Teresa CSIC ORCID ; Villa, Rosa CSIC ORCID ; Sánchez-Vives, María V. CSIC ORCID
Palabras claveNeural recording
Slow oscillations
Low impedance
Neural interfaces
SNR
Fecha de publicación29-nov-2018
EditorFrontiers Media
CitaciónFrontiers in Neuroscience 12: 862 (2018)
ResumenDeveloping new standardized tools to characterize brain recording devices is critical to evaluate neural probes and for translation to clinical use. The signal-to-noise ratio (SNR) measurement is the gold standard for quantifying the performance of brain recording devices. Given the drawbacks with the SNR measure, our first objective was to devise a new method to calculate the SNR of neural signals to distinguish signal from noise. Our second objective was to apply this new SNR method to evaluate electrodes of three different materials (platinum black, Pt; carbon nanotubes, CNTs; and gold, Au) co-localized in tritrodes to record from the same cortical area using specifically designed multielectrode arrays. Hence, we devised an approach to calculate SNR at different frequencies based on the features of cortical slow oscillations (SO). Since SO consist in the alternation of silent periods (Down states) and active periods (Up states) of neuronal activity, we used these as noise and signal, respectively. The spectral SNR was computed as the power spectral density (PSD) of Up states (signal) divided by the PSD of Down states (noise). We found that Pt and CNTs electrodes have better recording performance than Au electrodes for the explored frequency range (5-1500 Hz). Together with two proposed SNR estimators for the lower and upper frequency limits, these results substantiate our SNR calculation at different frequency bands. Our results provide a new validated SNR measure that provides rich information of the performance of recording devices at different brain activity frequency bands (<1500 Hz).
Descripción6 Figuras
URIhttp://hdl.handle.net/10261/182074
DOI10.3389/fnins.2018.00862
Identificadoresdoi: 10.3389/fnins.2018.00862
issn: 1662-453X
e-issn: 1662-453X
Aparece en las colecciones: (ICB) Artículos
(IMB-CNM) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Front. Neurosci._2018_Sanzchez-Vives.pdf2,82 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

10
checked on 13-abr-2024

SCOPUSTM   
Citations

29
checked on 28-abr-2024

WEB OF SCIENCETM
Citations

27
checked on 26-feb-2024

Page view(s)

332
checked on 03-may-2024

Download(s)

219
checked on 03-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


Este item está licenciado bajo una Licencia Creative Commons Creative Commons