Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/177983
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Minimising mortality in endangered raptors due to power lines: The importance of spatial aggregation to optimize the application of mitigation measures

AutorGuil, Francisco; Fernández-Olalla, Mariana; Moreno-Opo, Rubén; Mosqueda, Juan; Gómez, María Elena; Aranda, Antonio; Arredondo, Ángel; Guzmán, José Luis CSIC ORCID; Oria, Javier; González, Luis Mariano; Margalida, Antoni CSIC ORCID
Fecha de publicación2011
EditorPublic Library of Science
CitaciónPLoS ONE 6(11): e28212 (2011)
ResumenElectrocution by power lines is one of the main causes of non-natural mortality in birds of prey. In an area in central Spain, we surveyed 6304 pylons from 333 power lines to determine electrocution rates, environmental and design factors that may influence electrocution and the efficacy of mitigation measures used to minimise electrocution cases. A total of 952 electrocuted raptors, representing 14 different species, were observed. Electrocuted raptors were concentrated in certain areas and the environmental factors associated with increased electrocution events were: greater numbers of prey animals; greater vegetation cover; and shorter distance to roads. The structural elements associated with electrocutions were shorter strings of insulators, one or more phases over the crossarm, cross-shaped design and pylon function. Of the 952 carcasses found, 148 were eagles, including golden eagle (Aquila chrysaetos), Spanish imperial eagle (Aquila adalberti) and Bonelli's eagle (Aquila fasciata). Electrocuted eagles were clustered in smaller areas than other electrocuted raptors. The factors associated with increased eagle electrocution events were: pylons function, shorter strings of insulators, higher slopes surrounding the pylon, and more numerous potential prey animals. Pylons with increased string of insulators had lower raptor electrocution rates than unimproved pylons, although this technique was unsuccessful for eagles. Pylons with cable insulation showed higher electrocution rates than unimproved pylons, both for raptors and eagles, despite this is the most widely used and recommended mitigation measure in several countries. To optimize the application of mitigation measures, our results recommend the substitution of pin-type insulators to suspended ones and elongating the strings of insulators.
Versión del editorhttps://doi.org/10.1371/journal.pone.0028212
URIhttp://hdl.handle.net/10261/177983
DOI10.1371/journal.pone.0028212
E-ISSN1932-6203
Aparece en las colecciones: (IREC) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
minimioptimi.PDF348,96 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

PubMed Central
Citations

8
checked on 09-abr-2024

SCOPUSTM   
Citations

64
checked on 03-may-2024

WEB OF SCIENCETM
Citations

56
checked on 25-feb-2024

Page view(s)

216
checked on 03-may-2024

Download(s)

176
checked on 03-may-2024

Google ScholarTM

Check

Altmetric

Altmetric


Artículos relacionados:


Este item está licenciado bajo una Licencia Creative Commons Creative Commons