Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/158560
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Recent developments of the 1 MV AMS facility at the Centro Nacional de Aceleradores

AutorScognamiglio, Grazia CSIC; Chamizo, Elena CSIC ORCID; López-Gutiérrez, J. M. CSIC ORCID; Müller, A. M.; Padilla, Santiago CSIC; Santos, F. J. CSIC ORCID; López-Lora, Mercedes CSIC ORCID; Vivo Vilches, Carlos CSIC ORCID; García-León, Manuel CSIC ORCID
Palabras claveLow-energy AMS
AMS
CNA
Fecha de publicación2016
EditorElsevier
CitaciónNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 375: 17-25 (2016)
ResumenThe Centro Nacional de Aceleradores (CNA) hosts a 1 MV accelerator mass spectrometry (AMS) apparatus since September 2005. In order to improve its overall performance, several updates have been made on the existing facility during the last 10 years of operation. In this paper, two modifications conducted in 2015 will be described. To increase the transmission of the ions through the accelerator, the stripping gas on the 1 MV CNA machine was changed from Ar to He. The measured maximum transmission for almost every isotope results to be higher, especially for heavy masses: for instance, in the case of uranium in the 3+ charge state, the transmission increased from 11% with Ar gas to about 38% with He gas. The second advance consisted of the substitution of the existing gas ionization chamber with a new one provided by ETH Zurich. The ETH detector features with its miniaturized design and is optimized for low energy AMS (i.e. very low electronic noise and efficient charge collection). As the electronic noise is the most important contribution to the resolution for light ions, the total energy resolution has been reduced by 15% in the case of Be, allowing a better discrimination against its isobar, B. For the heaviest radionuclides where the quality of the spectra is determined by the charge carrier production in the gas, the resolution for 2.7 MeV uranium ions was improved by 30%, probably due to a more efficient charge collection.
URIhttp://hdl.handle.net/10261/158560
DOI10.1016/j.nimb.2016.03.033
Identificadoresdoi: 10.1016/j.nimb.2016.03.033
issn: 0168-583X
Aparece en las colecciones: (CNA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

16
checked on 20-abr-2024

WEB OF SCIENCETM
Citations

16
checked on 27-feb-2024

Page view(s)

226
checked on 27-abr-2024

Download(s)

76
checked on 27-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.