dc.contributor.authorSarrate, Ramon-
dc.contributor.authorNejjari, Fatiha-
dc.contributor.authorRosich, Albert-
dc.date.accessioned2014-06-03T08:35:25Z-
dc.date.available2014-06-03T08:35:25Z-
dc.date.issued2012-
dc.identifier.citationICSC 2012-
dc.identifier.urihttp://hdl.handle.net/10261/97613-
dc.descriptionPresentado al 2nd International Conference on Systems and Control celebrado en Marruecos del 20 al 22 de junio de 2012.-
dc.description.abstractThis paper presents a strategy based on fault diagnosability maximization to optimally locate sensors in complex systems. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of diagnosability and does not exceed a maximum sensor configuration cost. The strategy is based on the structural system model. Structural analysis is a powerful tool for dealing with complex nonlinear systems. The proposed approach is successfully applied to a Fuel Cell Stack System.-
dc.description.sponsorshipThis work has been funded by the Spanish Ministry of Science and Technology through the following projects CICYT WATMAN DPI2009-13744 and CICYT SHERECS DPI2011- 26243 and by European Comission through contract i-Sense FP7-ICT-2009- 6-270428.-
dc.relationinfo:eu-repo/grantAgreement/EC/FP7/270428-
dc.relation.isversionofPublisher's version-
dc.rightsopenAccess-
dc.subjectFault detection-
dc.subjectProcess control and instrumentation-
dc.subjectOptimization-
dc.titleSensor placement for fault diagnosis performance maximization under budgetary constraints-
dc.typecomunicación de congreso-
dc.date.updated2014-06-03T08:35:26Z-
dc.description.versionPeer Reviewed-
dc.language.rfc3066eng-
dc.contributor.funderEuropean Commission-
dc.contributor.funderMinisterio de Ciencia y Tecnología (España)-
dc.relation.csic-
dc.identifier.funderhttp://dx.doi.org/10.13039/501100000780es_ES
dc.identifier.funderhttp://dx.doi.org/10.13039/501100006280es_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_5794es_ES
item.openairetypecomunicación de congreso-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
Aparece en las colecciones: (IRII) Comunicaciones congresos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Sensor placement.pdf125,45 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

Page view(s)

166
checked on 23-abr-2024

Download(s)

319
checked on 23-abr-2024

Google ScholarTM

Check


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.