Título

Laboratory and field assessment of the capacitance sensors Decagon 10HS and 5TE for estimating the water content of irrigated soils

AutorVisconti Reluy, Fernando ; Paz Bécares, José Miguel de; Martínez, D.; Molina, M. J.
Palabras claveIrrigated clayey soils
SE Spain
Model calibration
Electrical conductivity
Field validation
Dielectric permittivity measurements
Fecha de publicaciónene-2014
EditorElsevier
CitaciónAgricultural Water Management 132: 111-119 (2014)
ResumenCapacitance sensors such as Decagon 10HS and 5TE are increasingly used for soil water content (θ) estimation. However, their reliability and limitations in clayey soils irrigated with saline waters have not been completely characterized under field conditions. Four levels of soil water content were combined with six levels of soil salinity in twenty-four pots to assess the performance of both sensors in a wide range of soil salinities. A simplified power-law dielectric mixing model was calibrated in the laboratory to estimate the θ of a clay loam soil from the measurements of apparent dielectric permittivity (e{open}b) performed with both sensors. The calibrated equation was subsequently validated for the estimation of θ at two depths in six irrigated salt-threatened soils with clayey textures in SE Spain. The 10HS sensor provides higher estimations of e{open}b than the 5TE. Besides, the 5TE sensor was more sensitive to soil salinity. Consequently, a different calibration was carried out for each sensor. When all the soil salinity treatments were included in the calibrations, the results were poor. However, for soil apparent electrical conductivities below 1.7dSm-1 the 5TE sensor could be calibrated with low prediction errors, and with the calibration parameters b0 and b1 very close to their characteristic values in clayey and mineral soils. In field testing, the 5TE sensors calibrated with the obtained equation provided average correct estimations with an error of ±0.05m3m-3. On the contrary, the 10HS sensor overestimated the soil water content by 0.07m3m-3 on average. The proposed simple calibration equation for the 5TE sensor can be reliably used under field conditions to estimate θ of irrigated clayey soils up to an apparent electrical conductivity of 1.7dSm-1. © 2013 Elsevier B.V.
Versión del editorhttps://doi.org/10.1016/j.agwat.2013.10.005
URIhttp://hdl.handle.net/10261/94792
DOI10.1016/j.agwat.2013.10.005
Identificadoresissn: 0378-3774
Aparece en las colecciones: (CIDE) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 

Artículos relacionados:


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.