English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/9049
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 17 veces en Web of Knowledge®  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar otros formatos: Exportar EndNote (RIS)Exportar EndNote (RIS)Exportar EndNote (RIS)
Título

Suitability of Filofocon A and PMMA for experimental models in excimer laser ablation refractive surgery

Autor Dorronsoro, Carlos ; Siegel, Jan ; Remón, Laura; Marcos, Susana
Palabras clave [OCIS] Ablation of tissue
[OCIS] Medical optics instrumentation
[OCIS] Surface measurements, figure
[OCIS] Laser materials processing
[OCIS] Physiological optics
[OCIS] Ophthalmic optics
[OCIS] Visual optics, refractive surgery
[OCIS] Aberration compensation
Fecha de publicación 3-dic-2008
EditorOptical Society of America
Citación Optics Express 16(25): 20955-20967 (2008)
ResumenExperimental corneal models in plastic (in PMMA, and more recently in Filofocon A, a contact lens material) have been proposed recently to overcome some of the limitations of the theoretical approaches aiming at improving the predictability of corneal reshaping by laser ablation. These models have also been proposed for accurate assessment of corneal laser ablation patterns. In this study Filofocon A and PMMA optical and ablation properties were studied using an experimental excimer laser set-up. The effective absorption coefficient and the ablation thresholds of these materials were obtained as a function of the number of pulses. Both materials follow a Beer-Lambert law in the range of fluences used in refractive surgery, and the number of incubation pulses is less than 4 (PMMA) and 2 (Filofocon A) above 140 mJ/cm2. We found that above 40 pulses for Filofocon A and 70 pulses for PMMA, ablation threshold and effective absorption coefficients can be considered constant (Fth = 90 mJ/cm2 and α(eff) = 36000 cm-1, for Filofocon A, and Fth = 67 mJ/cm2 and α(eff) = 52000 cm-1 for PMMA, respectively). The absence of ablation artifacts (central islands), a lower number of incubation pulses, a lower pulse-number dependence of the ablation threshold, and a good correspondence between α(eff) and the absorption coefficient α estimated from spectroscopic measurements make Filofocon A a more appropriate material than PMMA for experimental models in refractive surgery and for calibration of clinical lasers.
Descripción 13 pages, 7 figures.-- OCIS codes: 170.1020, 170.3890, 120.6650, 140.3390, 330.5370, 330.4460, 330.7335, 220.1000.
Versión del editorhttp://dx.doi.org/10.1364/OE.16.020955
URI http://hdl.handle.net/10261/9049
DOI10.1364/OE.16.020955
ISSN1094-4087
Aparece en las colecciones: (CFMAC-IO) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Suitability_of_Filofocon.pdf247,69 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.