Fully-automated fluorimetric determination of aluminum in seawater by in-syringe dispersive liquid-liquid microextraction using lumogallion

AutorSuárez, Ruth; Horstkotte, Burkhard CSIC ORCID; Duarte, Carlos M. CSIC ORCID; Cerdà, Víctor
Fecha de publicación2012
EditorAmerican Chemical Society
CitaciónAnalytical Chemistry 84(21): 9462-9469 (2012)
ResumenA sensitive and selective automated in-syringe dispersive liquid-liquid microextraction (DLLME) method is presented. It was successfully applied to the determination of aluminum in coastal seawater samples. The complete analytical procedure including sampling, buffering, reaction of the analyte with fluorescence reagent lumogallion (LMG), extraction, phase separation, and quantification was completely automized and carried out within 4 min. DLLME was done using n-hexanol as an extracting solvent and ethanol as a dispersing solvent in a 1:8 v/v percent mixture. The Al-LMG complex was extracted by an organic solvent and separated from the aqueous phase within the syringe of an automated syringe pump. Two devices were specially developed for this work. These were (a) the fluorescence detector and accompanying flow cell for the organic phase enriched with the reaction product and (b) a heating device integrated into the holding coil to accelerate the slow reaction kinetics. The limits of detection (3ο) and quantification (10ο) were 8.0 ± 0.5 nmol L -1 and 26.7 ± 1.6 nmol L -1, respectively. The relative standard deviation for eight replicate determinations of 200 nmol L -1 Al 3+ was <1.5%. The calibration graph using the preconcentration system was linear up to 1000 nmol L -1 with a correlation coefficient of 0.999. Ambient concentrations of samples were quantifiable with found concentrations ranging from 43 to 142 nmol L -1. Standard additions gave analyte recoveries from 97% to 113% proving the general applicability and adequateness of the analyzer system to real sample analysis. © 2012 American Chemical Society.
URIhttp://hdl.handle.net/10261/88769
DOI10.1021/ac302083d
Identificadoresdoi: 10.1021/ac302083d
issn: 0003-2700
Aparece en las colecciones: (IMEDEA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

51
checked on 20-abr-2024

WEB OF SCIENCETM
Citations

46
checked on 25-feb-2024

Page view(s)

346
checked on 22-abr-2024

Download(s)

102
checked on 22-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.