English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/8823
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Citado 15 veces en Web of Knowledge®  |  Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar otros formatos: Exportar EndNote (RIS)Exportar bibText (RIS)Exportar csv (RIS)
Título

Determination of the foveal cone spacing by ocular speckle interferometry: Limiting factors and acuity predictions

AutorMarcos, Susana ; Navarro, Rafael
Palabras claveHuman eye
Fovea
Photoreceptors
Cone spacing
Speckle interferometry
Fecha de publicación1-abr-1997
EditorOptical Society of America
CitaciónJournal of the Optical Society of America A 14(4): 731-740 (1997)
ResumenWe have developed a high-resolution imaging technique, based on speckle interferometry, for the objective determination of the cone spacing in the living human fovea. The spatial resolution attained with this technique is theoretically diffraction limited by the pupil size. However, the highest frequency that we measure varies greatly among subjects, especially for fully dilated pupils. We have conducted several experiments (determination of the cutoff frequency of ocular speckle interferometry, the double-pass modulation transfer function, and the Stiles-Crawford effect) that indicate that, as expected, the resolution is not limited by the incoherent modulation transfer function. We found, though, a high correlation between the cutoff frequency and the width of the eye's Stiles-Crawford function. This implies that the resolution depends on the structural properties of the cone mosaic itself. In addition, we have compared the Nyquist frequency of the cone mosaic, determined objectively by our technique, with the grating visual acuity measured in the same eyes at the same foveal eccentricities. For our subjects, visual resolution nearly matches the Nyquist frequency within the fovea, except at the foveal center, where the optical transfer function of the eye attenuates the contrast of frequencies close to the Nyquist limit to a value below threshold.
Descripción10 pages, 8 figures.-- PMID: 9088086 [PubMed].
Versión del editorhttp://dx.doi.org/10.1364/JOSAA.14.000731
URIhttp://hdl.handle.net/10261/8823
DOI10.1364/JOSAA.14.000731
ISSN1084-7529
Aparece en las colecciones: (CFMAC-IO) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 



NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.