English   español  
Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/8791
Compartir / Impacto:
Estadísticas
Add this article to your Mendeley library MendeleyBASE
Ver citas en Google académico
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar otros formatos: Exportar EndNote (RIS)Exportar EndNote (RIS)Exportar EndNote (RIS)
Título

Ocular Aberrations before and after Myopic Corneal Refractive Surgery: LASIK-Induced Changes Measured with Laser Ray Tracing

Autor Moreno Barriuso, Esther; Merayo-Lloves, Jesús; Marcos, Susana ; Navarro, Rafael
Palabras clave Optical aberrations
Refractive surgery
Laser in situ keratomileusis (LASIK)
Laser ray tracing
Root-mean-square (RMS) wavefront error
Image quality
Fecha de publicación may-2001
EditorAssociation for Research in Vision and Ophthalmology
Lippincott Williams & Wilkins
Citación Investigative Ophthalmology & Visual Science 42(6): 1396-1403 (2001)
Resumen[Purpose] To determine objectively the changes in the ocular aberrations (3rd order and above) induced by myopic LASIK refractive surgery and its impact on image quality.
[Methods] The ocular aberrations of 22 normal myopic eyes (preoperative refraction ranged from -13 to -2 D) were measured before (2.9 ± 4.3 weeks) and after (7.7 ± 3.2 weeks) LASIK refractive surgery using a laser ray tracing technique. A set of laser pencils is sequentially delivered onto the eye through different pupil locations. For each ray, the corresponding retinal image is collected on a CCD camera. The displacement of the image centroid with respect to a reference provides direct information of the ocular aberrations. Root-mean-square (RMS) wavefront error was taken as image quality metric.
[Results] RMS wavefront error increased significantly in all eyes but two after surgery. On average, LASIK induced a significant (P = 0.0003) 1.9-fold increase in the RMS error for a 6.5-mm pupil. The main contribution was due to the increase (fourfold, P < 0.0001) of spherical aberration. The increase in the RMS for a 3-mm pupil (1.7-fold) was also significant (P = 0.02). The modulation transfer (computed for 6.5-mm pupil) decreased on average by a factor of 2 for middle-high spatial frequencies.
[Conclusions] (1) Laser ray tracing is a well-suited, robust, and reliable technique for the evaluation of the change of ocular aberrations with refractive surgery. (2) Refractive surgery induces important amounts of 3rd and higher order aberrations. The largest increase occurs for spherical aberration. Decentration of the ablation pattern seems to generate 3rd order aberrations. (3) This result is important for the design of customized ablation algorithms, which should cancel existing preoperative aberrations while avoiding the generation of new aberrations.
Descripción 8 pages, 8 figures.-- PMID: 11328757 [PubMed].-- Open Access full-text paper available at the publisher's site.
Versión del editorhttp://www.iovs.org/cgi/content/abstract/42/6/1396/
URI http://hdl.handle.net/10261/8791
ISSN0146-0404
Aparece en las colecciones: (CFMAC-IO) Artículos
Ficheros en este ítem:
No hay ficheros asociados a este ítem.
Mostrar el registro completo
 


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.