Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/8773
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorBarbero, Sergio-
dc.contributor.authorMarcos, Susana-
dc.contributor.authorMerayo-Lloves, Jesús-
dc.date.accessioned2008-11-24T17:36:25Z-
dc.date.available2008-11-24T17:36:25Z-
dc.date.issued2002-09-09-
dc.identifier.citationJournal of Cataract and Refractive Surgery 28(9): 1594-1600 (2002)en_US
dc.identifier.issn0886-3350-
dc.identifier.urihttp://hdl.handle.net/10261/8773-
dc.description7 pages, 3 figures.-- PMID: 12231318 [PubMed].en_US
dc.description.abstract[Purpose] To measure corneal and total optical aberrations in the normal and treated eye of a unilateral aphakic patient to (1) cross-validate techniques in an eye in which corneal and total aberrations should be almost identical (aphakic eye) and (2) compare the interactions of corneal and internal aberrations in the normal eye with those in the aphakic eye.en_US
dc.description.abstract[Setting] Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Madrid, Spain.en_US
dc.description.abstract[Methods] Aberrations in both eyes of a unilateral aphakic patient were measured using laser ray tracing. Corneal aberrations were obtained from corneal elevation data measured with a corneal videokeratoscope (Humphrey Instruments) using custom software that performs virtual ray tracing on the measured front corneal surface.en_US
dc.description.abstract[Results] There was a 98.4% correspondence between the total and corneal aberration pattern in the aphakic eye (6.5 mm pupil). In the normal eye, the total spherical aberration was much lower than the corneal spherical aberration; this did not occur in the aphakic eye.en_US
dc.description.abstract[Conclusions] The posterior corneal surface contributed slightly to the aberrations in the normal cornea (2% at most). The crystalline lens appears to play a compensatory role in the total spherical aberration in normal eyes.en_US
dc.description.sponsorshipSponsored by research grants TIC98-0925-C02-01, Ministerio de Educación y Cultura and CAM:08.7/0010/2000 (Comunidad Autónoma de Madrid), Spain. Consejo Superior de Investigaciones Científicas and Carl Zeiss, Spain, sponsored a research fellowship (Barbero). Carl Zeiss provided a Mastervue Atlas Corneal Topography System.en_US
dc.format.extent181907 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.publisherAmerican Society of Cataract & Refractive Surgery-
dc.publisherAmerican Society of Cataract & Refractive Surgery-
dc.rightsclosedAccessen_US
dc.subjectHuman eyeen_US
dc.subjectOptical aberrationsen_US
dc.subjectAphakic eyeen_US
dc.subjectCorneal aberrationsen_US
dc.subjectIntraocular Lenses (IOLs)en_US
dc.titleCorneal and total optical aberrations in a unilateral aphakic patienten_US
dc.typeartículoen_US
dc.identifier.doi10.1016/S0886-3350(02)01368-8-
dc.description.peerreviewedPeer revieweden_US
dc.relation.publisherversionhttp://dx.doi.org/10.1016/S0886-3350(02)01368-8en_US
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.languageiso639-1en-
Aparece en las colecciones: (CFMAC-IO) Artículos
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

64
checked on 21-abr-2024

WEB OF SCIENCETM
Citations

57
checked on 23-feb-2024

Page view(s)

344
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.