Título: | Double-Pass Measurement of Retinal Image Quality in the Chicken Eye |
Autor: | Coletta, Nancy J.; Marcos, Susana CSIC ORCID ; Wildsoet, Christine; Troilo, David | Palabras clave: | Chickens Optical quality Aberrations Modulation transfer function Refractive error Myopia Animal models |
Fecha de publicación: | ene-2003 | Editor: | American Academy of Optometry Lippincott Williams & Wilkins |
Citación: | Optometry and Vision Science 80(1): 50-57 (2003) | Resumen: | [Purpose] The chicken, Gallus gallus domesticus, is used as an animal model to study the development of refractive error. Although vision is important in determining the eye's refractive state, relatively little is known about the retinal image quality of the chicken eye. An objective double-pass technique was used to measure the optical quality of the eyes of White Leghorn chickens. [Methods] Measurements were made on 21 eyes of six untreated birds and eight experimental birds that were members of a study of refractive development. Ages ranged from 3 to 6 weeks, and refractions ranged from -1.29 to +0.58 D in the untreated eyes and -4.58 to +10.17 D in the experimental eyes. The measurements were made under general anesthesia combined with either cycloplegia or ciliary nerve section. Proper optical alignment of the eye was achieved with the aid of a TV monitor, CCD camera, and an infrared source. A 543-nm laser point source was focused on the retina, and the double-pass aerial image was collected by a high-resolution CCD camera. Refractive errors were corrected with trial lenses, using a bracketing method to optimize the retinal images. Both the full width at half-maximum of the double-pass aerial image and the single-pass modulation transfer function were used as objective estimates of the optical quality. [Results] The mean full width at half-maximum value in eyes of the untreated birds was 1.60 min arc for a 4.50-mm mean pupil diameter. Optical quality tended to be worse in the experimental myopic eyes. [Conclusions] The optical quality of the chicken eye measured under monochromatic conditions meets or may even exceed the neural limits of spatial acuity based on anatomical estimates of ganglion cell spacing. The data also suggest that optical quality is worse in myopic eyes, which is consistent with studies of human eyes. |
Descripción: | 8 pages, 6 figures.-- PMID: 12553544 [PubMed].-- This research was presented as a paper at the annual meeting of the Association for Research in Vision and Ophthalmology on May 4, 2000, in Ft. Lauderdale, FL. | Versión del editor: | http://www.optvissci.com/pt/re/ovs/abstract.00006324-200301000-00008.htm | URI: | http://hdl.handle.net/10261/8652 | ISSN: | 1040-5488 | E-ISSN: | 1538-9235 |
Aparece en las colecciones: | (CFMAC-IO) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Double_pass_measurement.pdf | 654 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
Page view(s)
327
checked on 19-abr-2024
Download(s)
312
checked on 19-abr-2024
Google ScholarTM
Check
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.