Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/81927
COMPARTIR / EXPORTAR:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Testing of a pulsed He supersonic beam for plasma edge diagnostic in the TJ-IU torsatron

AutorTabarés, Francisco L.; Tafalla, David; Herrero, Víctor J. CSIC ORCID; Tanarro, Isabel CSIC ORCID
Fecha de publicación1997
EditorElsevier
CitaciónJournal of Nuclear Materials 241: 1228- 1233 (1997)
ResumenA new, compact atomic beam source based on the supersonic expansion of He has been developed for application as a plasma edge diagnostic. The beam is produced from a pulsed valve with a duration between 0.2 to 2 ms and a nominal repetition rate < 500 Hz. A terminal speed ratio > 10 and a divergence of ± 1° have been achieved at stagnation pressures below 2 bar. The diagnostic has been tested in ECRH plasmas on the TJ-IU torsatron, representing the first application of a supersonic beam to plasma characterization, to our knowledge. Operational conditions which minimized the total amount of He injected into the plasma were chosen. Non-perturbative injection conditions in the low density plasmas could be obtained at local He densities of ⋍ 1 × 1011 cm−3 and a beam diameter < 1 cm. Due to the relatively low electron density of the ECRH plasmas, and to the good penetration characteristics of the supersonic He beam, the diagnostic could be used up to fairly low values of the normalized plasma minor radius, View the MathML source. Details of the optimization of the atomic beam diagnostics and typical results for steady state conditions in the TJ-IU plasmas are presented. © 1997 Elsevier Science B.V.
Versión del editorhttp://dx.doi.org/10.1016/S0022-3115(97)80225-5
URIhttp://hdl.handle.net/10261/81927
DOI10.1016/S0022-3115(97)80225-5
Identificadoresdoi: 10.1016/S0022-3115(97)80225-5
issn: 0022-3115
Aparece en las colecciones: (CFMAC-IEM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
1997-Tabarés-Pulsed supersonic He beams.pdf1,25 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

292
checked on 17-abr-2024

Download(s)

299
checked on 17-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.