dc.description.abstractThis paper presents the results obtained in a study of the galvanic protection of steel provided by 55% Al-Zn coatings relative to zinc coatings (Sendzimir) in the atmosphere. While 55% Al-Zn coatings exhibit a passive behaviour under low aggressive atmospheres (e.g. in rural and urban areas), they provide good anodic performance (comparable to that of zinc coatings) under marine atmospheres.-
dc.language.isoeng-
dc.publisherJohn Wiley & Sons-
dc.rightsclosedAccess-
dc.titleAtmospheric galvanic protection of 55% Al-Zn precoated steel | Atmospharischer galvanischer Schutz von 55% Al-Zn Ueberzuegen-
dc.typeartículo-
dc.identifier.doi10.1002/maco.19940451003-
dc.date.updated2013-05-17T08:34:57Z-
dc.description.versionPeer Reviewed-
Appears in Collections:(CENIM) Artículos
Files in This Item:
File Description SizeFormat 
accesoRestringido.pdf15,38 kBAdobe PDFThumbnail
View/Open
Show simple item record
 


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.