Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/74957
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Chamizo, Elena | - |
dc.contributor.author | Jiménez-Ramos, M. C. | - |
dc.contributor.author | García-León, Manuel | - |
dc.contributor.author | García-Tenorio, R. | - |
dc.date.accessioned | 2013-04-23T12:02:40Z | - |
dc.date.available | 2013-04-23T12:02:40Z | - |
dc.date.issued | 2008 | - |
dc.identifier | doi: 10.1016/j.aca.2007.11.005 | - |
dc.identifier | issn: 0003-2670 | - |
dc.identifier | e-issn: 1873-4324 | - |
dc.identifier.citation | Analytica Chimica Acta 606(2): 239-245 (2008) | - |
dc.identifier.uri | http://hdl.handle.net/10261/74957 | - |
dc.description.abstract | A radiochemical method for the isolation of plutonium-isotopes from environmental samples, based on the use of specific extraction chromatography resins for actinides (TEVA®, Eichrom Industries, Inc.), has been set up in our laboratory and optimised for their posterior determination by alpha spectrometry (AS) or accelerator mass spectrometry (AMS). The proposed radiochemical method has replaced in our lab a well-established one based on the use of a relatively un-specific anion-exchange resin (AG® 1X8, Bio-rad Laboratories, Inc.), because it is clearly less time consuming, reduces the amounts and molarities of acid wastes produced, and reproducibly gives high radiochemical yields. In order to check the reliability of the proposed radiochemical method for the determination of plutonium-isotopes in different environmental matrixes, twin aliquots of a set of samples were prepared with TEVA® and with AG® 1X8 resins and measured by AS. Some samples prepared with TEVA® resins were measured as well by AMS. As it is shown in the text, there is a comfortable agreement between AS and AMS, which adequately validates the method. © 2007 Elsevier B.V. All rights reserved. | - |
dc.description.sponsorship | This work has been financed through the projects FIS2004-0495 of the Spanish Ministry of Science and Education, and RNM419 of the Junta de Andalucía. | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier | - |
dc.rights | closedAccess | - |
dc.title | Isolation of Pu-isotopes from environmental samples using ion chromatography for accelerator mass spectrometry and alpha spectrometry | - |
dc.type | artículo | - |
dc.identifier.doi | 10.1016/j.aca.2007.11.005 | - |
dc.date.updated | 2013-04-23T12:02:40Z | - |
dc.description.version | Peer Reviewed | - |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | artículo | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
Aparece en las colecciones: | (CNA) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
38
checked on 22-abr-2024
WEB OF SCIENCETM
Citations
34
checked on 23-feb-2024
Page view(s)
338
checked on 24-abr-2024
Download(s)
107
checked on 24-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.