English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/74706
Share/Impact:
Statistics
logo share SHARE logo core CORE   Add this article to your Mendeley library MendeleyBASE

Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:

Title

Comparison of methods and application of alpha spectrometry and mass spectrometry techniques for 239Pu determination in biological samples

AuthorsHernández-Mendoza, Héctor; Chamizo, Elena ; Delgado, Antonio; García-León, Manuel ; Yllera, Abel
Issue Date2011
PublisherRoyal Society of Chemistry (UK)
CitationJournal of Analytical Atomic Spectrometry 26(7): 1509-1513 (2011)
AbstractThis work describes two methods for rapid and simple preparation of urine samples for determining the 239Pu content. The preparation of the samples was carried out by evaporation or coprecipitation of Pu, followed by acidic digestion in a microwave oven. The concentration and purification of Pu were achieved by using ion exchange resins AG1X2 and AG1X8 (Bio-Rad Laboratories). The quantification of 239Pu was carried out employing three different instrumental techniques, the more conventional Alpha Spectrometry (AS), and two mass spectrometry methods: High-Resolution Inductively Coupled Plasma Mass Spectrometry (HR-ICP-MS) and a low-energy Accelerator Mass Spectrometry (AMS). The chemical yield was determined by AS being, on average, 76 ± 7%. The minimum detectable activity (MDA) for AS, HR-ICP-MS and AMS was, respectively, about 50 fg (∼0.1 mBq), 23 fg (∼0.05 mBq) and 0.44 fg (∼1 Bq) per sample, respectively. The results presented in this work demonstrate the excellent performance and suitability of the mass spectrometric techniques for the routine measurement of 239Pu at ultratrace levels in human urine samples, and also for the reassessing of AS planchets if it were needed. The application of HR-ICP-MS and low-energy AMS reduces the sample processing time, and helps us to improve the laboratory productivity, also giving better MDA values when compared to the classical radiometric methods. © 2011 The Royal Society of Chemistry.
URIhttp://hdl.handle.net/10261/74706
DOI10.1039/C0JA00093K
Identifiersdoi: 10.1039/C0JA00093K
issn: 0267-9477
e-issn: 1364-5544
Appears in Collections:(CNA) Artículos
Files in This Item:
File Description SizeFormat 
accesoRestringido.pdf15,38 kBAdobe PDFThumbnail
View/Open
Show full item record
Review this work
 

Related articles:


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.