In vitro assessment of Staphylococcus epidermidis and Staphylococcus aureus adhesion on TiO 2 nanotubes on Ti-6Al-4V alloy

AutorPérez-Jorge, C.; Conde del Campo, Ana ; Arenas, M. A. CSIC ORCID; Pérez-Tanoira, R.; Matykina, E. CSIC ORCID; Damborenea, Juan de CSIC ORCID ; Gómez Barrena, Enrique; Esteban, Jaime
Fecha de publicación2012
EditorJohn Wiley & Sons
CitaciónJournal of Biomedical Materials Research - Part A 100 A: 1696- 1705 (2012)
ResumenThe aim of this study was to evaluate Staphylococcus sp. adhesion to modified surfaces of titanium alloy (Ti-6Al-4V). Specimens of Ti-6Al-4V alloy 6-4 ELI-grade 23 that meets the requirements of ASTM F136 2002A (AMS 2631B class A1) were anodized in a mixture of sulfuric/hydrofluoric acid at 20 V for 5 and 60 min to form nanoporous (NP) and nanotubular (NT) oxide layers with pore diameter of 20 and 100 nm, respectively. The amount of fluorine incorporated in the oxide films from the electrolyte was 6 and 4 wt %, respectively. Bacterial adherence was studied using laboratory strains and six clinical strains each of Staphylococcus aureus and Staphylococcus epidermidis. Lower adherence of laboratory strains was demonstrated on fluoride nanostructured surfaces in comparison with the fluoride-free surfaces. Significant differences between clinical strains and laboratory strains were also found (p < 0.0001, Kruskal-Wallis test) when NP and NT specimens were compared with chemically polished (CP) surfaces. The results of the tests using multiple clinical strains confirmed a decrease in bacterial adherence on F-containing titanium oxide surfaces, suggesting a potential applicability of this surface, with a confirmed added value of decreasing clinical staphylococci adherence, for medical prosthetic devices. © 2012 Wiley Periodicals, Inc.
URIhttp://hdl.handle.net/10261/74496
DOI10.1002/jbm.a.34118
Identificadoresdoi: 10.1002/jbm.a.34118
issn: 1549-3296
Aparece en las colecciones: (CENIM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

63
checked on 22-abr-2024

WEB OF SCIENCETM
Citations

55
checked on 29-feb-2024

Page view(s)

338
checked on 23-abr-2024

Download(s)

124
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.