Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/64599
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorSalmerón, Patricio-
dc.contributor.authorMontaño Asquerino, Juan Carlos-
dc.contributor.authorRodríguez Vázquez, Jesús-
dc.contributor.authorPrieto Thomas, J.-
dc.contributor.authorPérez Vallés, A.-
dc.date.accessioned2013-01-21T14:33:28Z-
dc.date.available2013-01-21T14:33:28Z-
dc.date.issued2004-
dc.identifierdoi: 10.1109/TPWRD.2004.829150-
dc.identifierissn: 0885-8977-
dc.identifier.citationIEEE Transactions on Power Delivery 19(4): 1968-1974 (2004)-
dc.identifier.urihttp://hdl.handle.net/10261/64599-
dc.description.abstractFor three-phase four-wire circuits, two compensation criteria have been established: one based on the instantaneous value concept and the other on the average value concept. Thus, according to the instantaneous value concept the non instantaneous power current is reduced, without altering the instantaneous active power. According to the average value concept, the nonactive average-current is reduced, without altering the average power. When the zero-sequence voltage component exists, both compensation types would not enable the zero-sequence (neutral) source current elimination. Then, two approaches are marked in this paper. The first one is for eliminating the non instantaneous power current or the nonactive average-current but the neutral current can still flow. The second one for eliminating the modified non instantaneous power current or the modified nonactive average-current, thus the neutral current component is compensated. According to recent recommendations in this work three-phase systems are considered as four-conductor systems. Experimental results are obtained to confirm the theoretical properties and to show the compensator performance.-
dc.description.sponsorshipThe “Comisión Interministerial de Ciencia y Tecnología (CICYT)” of the Spanish Minister of Education and Culture.-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers-
dc.rightsopenAccess-
dc.titleCompensation in nonsinusoidal, unbalanced three-phase four-wire systems with active power-line conditioner-
dc.typeartículo-
dc.identifier.doi10.1109/TPWRD.2004.829150-
dc.date.updated2013-01-21T14:33:29Z-
dc.description.versionPeer Reviewed-
dc.contributor.funderMinisterio de Educación y Cultura (España)-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairetypeartículo-
Aparece en las colecciones: (IRNAS) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
Compensation in nonsinusoidal, unbalanced.pdf1,12 MBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

69
checked on 09-abr-2024

WEB OF SCIENCETM
Citations

49
checked on 28-feb-2024

Page view(s)

326
checked on 16-abr-2024

Download(s)

437
checked on 16-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.