English   español  
Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/52007
Share/Impact:
Statistics
logo share SHARE   Add this article to your Mendeley library MendeleyBASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL
Exportar a otros formatos:
Title

Electrochemical magneto-immuno-PCR approach for direct and highly sensitive detection of Streptococcus pneumoniae

AuthorsCampuzano, Susana ; Esteban-Fernández de Ávila, Berta; Pedrero, María; García, José Luis ; García, Pedro ; García, Ernesto ; Pingarrón, José Manuel
KeywordsElectrochemical magnetoimmunosensing
PCR amplification
Streptococcus pneumoniae
Issue DateJan-2011
PublisherSimplex Academic Publishers
CitationChemical Sensors 1:8(2011)
AbstractA magneto-electrochemical immunoassay approach coupled to direct asymmetric PCR (DaPCR) of the bacteria attached to capture antibody-Protein A-magnetic beads (MBs) is reported. DaPCR was used to amplify a characteristic 235-bp region of the gene coding for the major pneumococcal autolysin (lytA). The predominantly single-stranded and biotinylated amplicons were subsequently hybridized onto streptavidin-MBs modified with a specific biotinylated 20-mer capture probe. After binding a streptavidin-peroxidase polymer to the resultant biotinylated hybrid, the modified MBs were captured by a magnet on the surface of a TTF-modified gold screenprinted electrode (Au/SPE). The amperometric response measured at 0.15 V after the addition of hydrogen peroxide was used to monitor the hybridization process. DaPCR amplicons could be obtained with only 20 cfu of Streptococcus pneumoniae (S. pneumoniae), whereas no amplicon was obtained in the presence of high concentrations (1.0x108 cfu mL-1) of other streptococci. The developed methodology allows an easy differentiation between 100 cfu mL-1 S. pneumoniae cultures and the asymmetric PCR blank control. Calibration curves were constructed for R6 and Dawn serotypes, with limits of detection (LODs) of 132 and 130 cfu mL-1, respectively. These values are approximately 100-1000 times lower than those obtained with disposable electrochemical magnetoimmunosensors without PCR amplification
Description7 páginas, 4 figuras, 1 tabla
URIhttp://hdl.handle.net/10261/52007
ISSN2231-6035
Appears in Collections:(CIB) Artículos
Files in This Item:
There are no files associated with this item.
Show full item record
Review this work
 


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.