Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/48933
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorMimendia, Aitor-
dc.contributor.authorLegin, Andrey-
dc.contributor.authorMerkoçi, Arben-
dc.contributor.authorValle, Manel del-
dc.date.accessioned2012-04-25T13:08:53Z-
dc.date.available2012-04-25T13:08:53Z-
dc.date.issued2010-04-
dc.identifier.citationSensors and Actuators B: Chemical 146(2): 420-426 (2010)es_ES
dc.identifier.issn0925-4005-
dc.identifier.urihttp://hdl.handle.net/10261/48933-
dc.description7 páginas, 5 figuras, 6 tablas.-- Trabajo presentado a: "The 13th International Symposium on Olfaction and Electronic Nose — ISOEN 2009".es_ES
dc.description.abstractAn automated potentiometric electronic tongue (ET) was developed for the quantitative determination of Cd2+, Cu2+ and Pb2+ heavy metal mixtures. The Sequential Injection Analysis (SIA) technique was used in order to automate the obtaining of input data. The combined response was modelled by means of Artificial Neural Networks (ANNs). The sensor array was formed by four Ion Selective Electrode (ISE) sensors: two based on chalcogenide glasses, Cd sensor and Cu sensor, and the rest on poly(vinyl chloride) membranes, Pb sensor and Zn sensor. The sensors were first characterized with respect to one and two analytes, by means of high-dimensionality calibrations, aided by the use of the SIA flow system; this characterization enabled an interference study of great practical utility. To take profit of the dynamic nature of the sensors response, each kinetic profile was compacted by Fast Fourier Transform (FFT) and the extracted coefficients used as inputs for the ANN in the multidetermination application. Finally, analyses were performed employing synthetic samples to validate obtained results.es_ES
dc.description.sponsorshipThis work was supported by European Community project FP6- IST No. 034472, “WARMER: Water risk management in Europe” and by Spanish Ministry of Science and Innovation, project TEC2007- 68012-C03-02/MIC.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsclosedAccesses_ES
dc.subjectHeavy metalses_ES
dc.subjectArtificial neural networkses_ES
dc.subjectPotentiometric sensorses_ES
dc.subjectSequential Injection Analysises_ES
dc.subjectAutomated electronic tonguees_ES
dc.titleUse of Sequential Injection Analysis to construct a potentiometric electronic tongue: Application to the multidetermination of heavy metalses_ES
dc.typeartículoes_ES
dc.identifier.doi10.1016/j.snb.2009.11.027-
dc.description.peerreviewedPeer reviewedes_ES
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.snb.2009.11.027es_ES
dc.contributor.funderEuropean Commission-
dc.contributor.funderMinisterio de Ciencia e Innovación (España)-
dc.identifier.funderhttp://dx.doi.org/10.13039/501100000780es_ES
dc.identifier.funderhttp://dx.doi.org/10.13039/501100004837es_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.languageiso639-1en-
Aparece en las colecciones: (CIN2) Artículos
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

50
checked on 12-abr-2024

WEB OF SCIENCETM
Citations

45
checked on 18-feb-2024

Page view(s)

261
checked on 19-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.