Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/47793
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorBoada, R.-
dc.contributor.authorLaguna-Marco, M. A.-
dc.contributor.authorGallastegui, J. A.-
dc.contributor.authorCastro, Germán R.-
dc.contributor.authorChaboy, Jesús-
dc.date.accessioned2012-04-02T10:00:23Z-
dc.date.available2012-04-02T10:00:23Z-
dc.date.issued2010-05-
dc.identifier.citationJournal of Synchrotron Radiation 17(3): 308-313 (2010)es_ES
dc.identifier.issn0909-0495-
dc.identifier.urihttp://hdl.handle.net/10261/47793-
dc.description6 páginas, 8 figuras.es_ES
dc.description.abstractCircularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism (XMCD) on the bending-magnet beamline BM25A (SpLine) at the ESRF. Field reversal and helicity reversal techniques have been used to carry out the measurements. The performance of the experimental set-up has been demonstrated by recording XMCD in the energy range from 7 to 11 keV.es_ES
dc.description.sponsorshipThis work was partially supported by a Spanish CICYTMAT2008- 06542-C04 grant. MALM and RB acknowledge the Ministerio de Ciencia e Innovación of Spain for their Postdoctoral and PhD grants, respectively. We also acknowledge the Spanish Ministerio de Ciencia e Innovación and Consejo Superior de Investigaciones Científicas for financial support.es_ES
dc.language.isoenges_ES
dc.publisherInternational Union of Crystallographyes_ES
dc.publisherWiley-Blackwelles_ES
dc.rightsopenAccesses_ES
dc.subjectX-ray magnetic circular dichroismes_ES
dc.subjectX-ray phase retarderes_ES
dc.subjectPolarization tunabilityes_ES
dc.subjectMagnetic polarizationes_ES
dc.titleX-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRFes_ES
dc.typeartículoes_ES
dc.identifier.doi10.1107/S0909049510005881-
dc.description.peerreviewedPeer reviewedes_ES
dc.relation.publisherversionhttp://dx.doi.org/10.1107/S0909049510005881es_ES
dc.identifier.e-issn1600-5775-
dc.identifier.pmid20400827-
local.message.claim2024-01-31T16:33:33.181+0100|||rp15348|||submit_approve|||dc_contributor_author|||None*
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.openairetypeartículo-
Aparece en las colecciones: (ICMA) Artículos
(ICMM) Artículos
Ficheros en este ítem:
Fichero Descripción Tamaño Formato
X-ray magnetic circular.pdf736,79 kBAdobe PDFVista previa
Visualizar/Abrir
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

4
checked on 19-abr-2024

WEB OF SCIENCETM
Citations

4
checked on 26-feb-2024

Page view(s)

343
checked on 24-abr-2024

Download(s)

250
checked on 24-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.