Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/47793
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Boada, R. | - |
dc.contributor.author | Laguna-Marco, M. A. | - |
dc.contributor.author | Gallastegui, J. A. | - |
dc.contributor.author | Castro, Germán R. | - |
dc.contributor.author | Chaboy, Jesús | - |
dc.date.accessioned | 2012-04-02T10:00:23Z | - |
dc.date.available | 2012-04-02T10:00:23Z | - |
dc.date.issued | 2010-05 | - |
dc.identifier.citation | Journal of Synchrotron Radiation 17(3): 308-313 (2010) | es_ES |
dc.identifier.issn | 0909-0495 | - |
dc.identifier.uri | http://hdl.handle.net/10261/47793 | - |
dc.description | 6 páginas, 8 figuras. | es_ES |
dc.description.abstract | Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism (XMCD) on the bending-magnet beamline BM25A (SpLine) at the ESRF. Field reversal and helicity reversal techniques have been used to carry out the measurements. The performance of the experimental set-up has been demonstrated by recording XMCD in the energy range from 7 to 11 keV. | es_ES |
dc.description.sponsorship | This work was partially supported by a Spanish CICYTMAT2008- 06542-C04 grant. MALM and RB acknowledge the Ministerio de Ciencia e Innovación of Spain for their Postdoctoral and PhD grants, respectively. We also acknowledge the Spanish Ministerio de Ciencia e Innovación and Consejo Superior de Investigaciones Científicas for financial support. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | International Union of Crystallography | es_ES |
dc.publisher | Wiley-Blackwell | es_ES |
dc.rights | openAccess | es_ES |
dc.subject | X-ray magnetic circular dichroism | es_ES |
dc.subject | X-ray phase retarder | es_ES |
dc.subject | Polarization tunability | es_ES |
dc.subject | Magnetic polarization | es_ES |
dc.title | X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF | es_ES |
dc.type | artículo | es_ES |
dc.identifier.doi | 10.1107/S0909049510005881 | - |
dc.description.peerreviewed | Peer reviewed | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1107/S0909049510005881 | es_ES |
dc.identifier.e-issn | 1600-5775 | - |
dc.identifier.pmid | 20400827 | - |
local.message.claim | 2024-01-31T16:33:33.181+0100|||rp15348|||submit_approve|||dc_contributor_author|||None | * |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.openairetype | artículo | - |
Aparece en las colecciones: | (ICMA) Artículos (ICMM) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
X-ray magnetic circular.pdf | 736,79 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
4
checked on 19-abr-2024
WEB OF SCIENCETM
Citations
4
checked on 26-feb-2024
Page view(s)
343
checked on 24-abr-2024
Download(s)
250
checked on 24-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.