Título

Estudio de la capacidad para intumescer de dos sistemas de pintura expuestos a ambientes internos agresivos

Otros títulosStudy of the capacity to intumesce of two paint systems exposed to aggressive internal environments
AutorChico, Belén; López-Delgado, Aurora CSIC ORCID ; Lobo-Recio, María de los Angeles; Fuente, Daniel de la CSIC ORCID; Castaño, J. G.; Morcillo, Manuel CSIC ORCID; López Gómez, Félix Antonio CSIC ORCID CVN
Palabras claveResistencia al fuego
Acero
Condiciones de exposición
FTIR
Fire resistance
Steel
Exposure conditions
FTIR
Fecha de publicación2005
EditorCSIC - Centro Nacional de Investigaciones Metalúrgicas (CENIM)
CitaciónRevista de Metalurgia 41 (Nº Extra) : 423-427 (2005)
Resumen[ES]Es conocida la influencia que ejerce la temperatura en la capacidad resistente del acero estructural. Un sistema de protección del acero, altamente efectivo, consiste en la utilización de pinturas intumescentes. Su efectividad se basa en el hecho de que, en el caso eventual de un incendio, al entrar en contacto con la llama reaccionan hinchándose y formando una capa aislante que se denomina "intumescencia" y que impide la propagación del calor. Estas pinturas no precisan de un mantenimiento continuo, aunque su comportamiento en servicio depende de las condiciones de exposición. Este trabajo estudia el comportamiento de dos sistemas intumescentes de tipo caucho acrilado expuestos en una planta de galvanizado durante 16 meses, valorando el efecto del medio ambiente sobre la capacidad para intumescer del recubrimiento cuando es sometido a un calentamiento.
[EN]The influence exerted by temperature on the resistant capacity of structural steel is well known. A highly efficient protection system for steel consists of the application of intumescent paints. In the case of fire, their effectiveness is based on the property that when they come into contact with flames they react by swelling to form an insulating layer, referred to as "intumescence", which impedes the propagation of heat. These paints do not require continuous maintenance though their service behaviour depends on the exposure conditions to which they are exposed. This paper studies the behaviour of two acrylated rubber type intumescent systems exposed to a galvanising plant for 16 months, evaluating the effect of the environment on the capacity to intumesce of the coating when subjected to heating.
Versión del editorhttp://revistademetalurgia.revistas.csic.es/index.php/revistademetalurgia/article/view/1068/1080
URIhttp://hdl.handle.net/10261/45321
ISSN0034-8570
Aparece en las colecciones: (CENIM) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
1080.pdf1,12 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

323
checked on 24-abr-2024

Download(s)

283
checked on 24-abr-2024

Google ScholarTM

Check


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.