Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/43626
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Campo DC Valor Lengua/Idioma
dc.contributor.authorFeo, María Luisa-
dc.contributor.authorEljarrat, Ethel-
dc.contributor.authorBarceló, Damià-
dc.date.accessioned2011-12-22T09:12:18Z-
dc.date.available2011-12-22T09:12:18Z-
dc.date.issued2010-
dc.identifier.citationJournal of Chromatography Aes_ES
dc.identifier.issn0021-9673-
dc.identifier.urihttp://hdl.handle.net/10261/43626-
dc.description.abstractA simple, efficient and environmentally friendly analytical methodology is proposed for extracting and preconcentrating pyrethroids from water samples prior to gas chromatography-negative ion chemical ionization mass spectrometry (GC-NCI-MS) analysis. Fourteen pyrethroids were selected for this work: bifenthrin, cyfluthrin, λ-cyhalothrin, cypermethrin, deltamethrin, esfenvalerate, fenvalerate, fenpropathrin, τ-fluvalinate, permethrin, phenothrin, resmethrin, tetramethrin and tralomethrin. The method is based on ultrasound-assisted emulsification-extraction (UAEE) of a water-immiscible solvent in an aqueous medium. Chloroform was used as extraction solvent in the UAEE technique. Target analytes were quantitatively extracted achieving an enrichment factor of 200 when 20 mL aliquot of pure water spiked with pyrethroid standards was extracted. The method was also evaluated with tap water and river water samples. Method detection limits (MDLs) ranged from 0.03 to 35.8 ng L−1 with RSDs values ≤3–25% (n = 5). The coefficients of estimation of the calibration curves obtained following the proposed methodology were ≥0.998. Recovery values were in the range of 45–106%, showing satisfactory robustness of the method for analyzing pyrethroids in water samples. The proposed methodology was applied for the analysis of river water samples. Cypermethrin was detected at concentration levels ranging from 4.94 to 30.5 ng L−1.es_ES
dc.description.sponsorshipEuropean Union and the Spanish Ministry of Education and Science (Projects numbers: CTM2005-25168-E, and CEMAGUA (CGL2007-64551/HID)).es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsclosedAccesses_ES
dc.subjectUltrasound-assisted emulsification-extractiones_ES
dc.subjectPyrethroid analysises_ES
dc.subjectWater analysises_ES
dc.subjectMass spectrometryes_ES
dc.titleA rapid and sensitive analytical method for the determination of 14 pyrethroids in water sampleses_ES
dc.typeartículoes_ES
dc.identifier.doi10.1016/j.chroma.2010.02.018-
dc.description.peerreviewedPeer reviewedes_ES
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.chroma.2010.02.018es_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeartículo-
item.cerifentitytypePublications-
item.grantfulltextnone-
Aparece en las colecciones: (IDAEA) Artículos
Show simple item record

CORE Recommender

SCOPUSTM   
Citations

73
checked on 22-abr-2024

WEB OF SCIENCETM
Citations

67
checked on 22-feb-2024

Page view(s)

412
checked on 24-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.