Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/43465
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Lopez-Soto-Yarritu, Pilar | - |
dc.contributor.author | Díez-Masa, José Carlos | - |
dc.contributor.author | Cifuentes, Alejandro | - |
dc.contributor.author | Frutos, Mercedes de | - |
dc.date.accessioned | 2011-12-19T11:07:36Z | - |
dc.date.available | 2011-12-19T11:07:36Z | - |
dc.date.issued | 2002 | - |
dc.identifier.citation | Journal of Chromatography A, 968 : 221–228 (2002) | es_ES |
dc.identifier.issn | 0021-9673 | - |
dc.identifier.uri | http://hdl.handle.net/10261/43465 | - |
dc.description.abstract | Human erythropoietin (EPO) is an endogenously produced glycoprotein, which plays a key role in the erythropoiesis process. Production of erythropoietin by recombinant DNA techniques has made possible its therapeutical use besides its misuse in sport competitions. The link between glycosylated form and protein activity makes necessary a method to analyze the glycoforms’ distribution in the recombinant products. In this work, a capillary isoelectric focusing (cIEF) method is presented that allows the analysis of erythropoietin glycoforms. Besides, the cIEF method can be easily implemented in different laboratories. In order to get a feasible and precise cIEF method the following factors have been studied and optimized: (i) neutral coated capillaries, 27 cm long are employed, (ii) ampholytes in the pH range 2 to 10 are used, (iii) bovine b-lactoglobulin A is chosen as internal standard, (iv) anolyte consisting of 91 mM H PO in cIEF gel is made by 3 4 weight and catholyte is prepared by titrating 20 mM NaOH with H PO to pH 11.85–11.90, (v) sample is completely 3 4 depleted of excipients and sodium chloride 10 mM final concentration is added, and (v) t /t and (A 2 A )/A , nn I.S. n I.S. I.S. being the recombinant EPO glycoform considered and I.S. the internal standard, are chosen as indexes to express migration time and area. As a result, a precise method to analyze erythropoietin by capillary isoelectric focusing is achieved with intra-assay RSD#0.5% for index time and #1.5% for index area and inter-sample, inter-anolyte, and inter-catholyte precision better than 3.4% for index time and RSD lower than 2.2% for index area. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | closedAccess | es_ES |
dc.subject | Isoelectric focusing | es_ES |
dc.subject | Erythropoietin | es_ES |
dc.subject | Glycoproteins | es_ES |
dc.subject | Proteins | es_ES |
dc.title | Improved capillary isoelectric focusing method for recombinant erythropoietin analysis | es_ES |
dc.type | artículo | es_ES |
dc.identifier.doi | 10.1016/S0021-9673(02)00783-5 | - |
dc.description.peerreviewed | Peer reviewed | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/S0021-9673(02)00783-5 | es_ES |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.openairetype | artículo | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
Aparece en las colecciones: | (IQOG) Artículos (IFI) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
accesoRestringido.pdf | 15,38 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
46
checked on 17-abr-2024
WEB OF SCIENCETM
Citations
36
checked on 23-feb-2024
Page view(s)
328
checked on 19-abr-2024
Download(s)
147
checked on 19-abr-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.