Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/35625
Share/Export:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE
DC FieldValueLanguage
dc.contributor.authorRodríguez Pérez, Pablo-
dc.contributor.authorNavarro, Rafael-
dc.contributor.authorArines Piferrer, Justo-
dc.contributor.authorBará, Salvador-
dc.date.accessioned2011-05-13T11:16:09Z-
dc.date.available2011-05-13T11:16:09Z-
dc.date.issued2006-
dc.identifier.urihttp://hdl.handle.net/10261/35625-
dc.description.abstractPurpose. To manufacture and test a set of phase plates for the calibration of ocular aberrometers and eventually to apply it to the calibration of an ocular laser ray tracing aberrometer. Methods. The set of phase plates is made by a grey-scale single-mask photosculpture in photoresist method. Each plate induces a given amount of a particular aberration (Zernike) mode. The set contains two subsets: (1) different pure Zernike modes to test the accuracy among different orders (from 3rd to 7th, about 0.3 - 0.4 microns); and (2) plates having different amounts of the same mode, 3rd order coma ranging from 0.11 to 0.47 microns. Right after manufacturing, the plates were tested twice, as a cross-check, measuring the aberration pattern of each plate with a Mach-Zehnder interferometer and a single-pass Hartmann-Shack wavefront sensor. The set was then applied to the calibration of an ocular double-pass laser ray tracing aberrometer. Results. We found a close agreement between the three types of measurement. The maximum difference between H-S and LRT measurements was 0.032 μm (that is about λ/20, half of the typical measuring error in human eyes). This permitted us to detect a small bias in the ocular laser ray tracing aberrometer. Conclusions. The calibration set may be a powerful tool for the assessment of accuracy and reliability in ocular aberrometry. It allowed us to discover a small bias, that is almost impossible to detect working with human eyes or trial lenses. This type of calibration tool is especially important in clinical environments.es_ES
dc.description.sponsorshipThis work has been partially supported by the Comisión Interministerial de Ciencia y Tecnología (Spain), under grant DPI2002-04370-C02.es_ES
dc.language.isoenges_ES
dc.rightsopenAccesses_ES
dc.titleA calibration set for ocular aberrometers: Manufacture, testing and applicationes_ES
dc.typeartículoes_ES
dc.description.peerreviewedPeer reviewedes_ES
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es_ES
item.openairetypeartículo-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Collections:(CFMAC-IO) Artículos
Files in This Item:
File Description SizeFormat
PhasePlates_JRS-2006.pdf8,49 MBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s)

224
checked on Jun 30, 2022

Download(s)

146
checked on Jun 30, 2022

Google ScholarTM

Check


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.