Título

The new multi-frequency instrument (MFI2) for the QUIJOTE facility in Tenerife

AutorHoyland, Roger J.; Rubiño-Martín, J. A.; Aguiar-González, Marta; Artal, Eduardo; Ashdown, Mark; Barreiro, R. Belén CSIC ORCID ; Casas-Reinares, F. J. CSIC ORCID ; Hoz, Elena de la CSIC ORCID; Génova-Santos, R.; Guidi, Federica; Hernández-Monteagudo, Carlos; Herranz, D. CSIC ORCID ; Lasenby, Anthony N.; López-Caraballo, Carlos H.; Martínez-González, Enrique CSIC ORCID ; Peel, Michael W.; Piccirillo, Lucio; Rebolo López, Rafael CSIC ORCID; Vielva, Patricio CSIC ORCID ; Watson, R. A.
Fecha de publicación2022
EditorSPIE digital library
CitaciónProceedings of SPIE 12190: 1219033 (2022)
ResumenThe QUIJOTE (Q-U-I joint Tenerife) experiment combines the operation of two radio-telescopes and three instruments working in the microwave bands 10–20 GHz, 26–36 GHz and 35–47 GHz at the Teide Observatory, Tenerife, and has already been presented in previous SPIE meetings (Hoyland, R. J. et al, 2012; Rubi˜no-Mart´ın et al., 2012). The Cosmology group at the IAC have designed a new upgrade to the MFI instrument in the band 10–20 GHz. The aim of the QUIJOTE telescopes is to characterise the polarised emission of the cosmic microwave background (CMB), as well as galactic and extra-galactic sources, at medium and large angular scales. This MFI2 will continue the survey at even higher sensitivity levels. The MFI2 project led by the Instituto de Astrof´ısica de Canarias (IAC) consists of five polarimeters, three of them operating in the sub-band 10–15 GHz, and two in the sub-band 15–20 GHz. The MFI2 instrument is expected to be a full two–three times more sensitive than the former MFI. The microwave complex correlator design has been replaced by a simple correlator design with a digital back-end based on the latest Xilinx FPGAs (ZCU111). During the first half of 2019 the manufacture of the new cryostat was completed and since then the opto-mechanical components have been designed and manufactured. It is expected that the cryogenic front-end will be completed by the end of 2022 along with the FPGA acquisition and observing system. This digital system has been employed to be more robust against stray ground-based and satellite interference, having a frequency resolution of 1 MHz.
DescripciónEvent: SPIE Astronomical Telescopes + Instrumentation, 2022, Montréal, Québec, Canada.
et al.
URIhttp://hdl.handle.net/10261/306559
DOI10.1117/12.2640826
E-ISSN1996-756X
Aparece en las colecciones: (IFCA) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
ThenewMultiFrequency.pdf17,71 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

WEB OF SCIENCETM
Citations

2
checked on 12-feb-2024

Page view(s)

37
checked on 23-abr-2024

Download(s)

26
checked on 23-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.