Title: | Identification of partially known models of the Susqueda hidroelectric power plant |
Authors: | Quiroga, Oscar Daniel; Riera, Jordi CSIC; Batlle, Carles | Keywords: | Identification Hydroelectric power plant Models Electric power production |
Issue Date: | 2003 | Publisher: | Universidad Nacional del Sur (Argentina) | Citation: | Latin American Applied Research, 33(4): 387-392 (2003) | Abstract: | This paper presents the identification of a hydroelectric power turbine dynamics. Knowledge of power plant behaviour is fundamental to obtain reliable and efficient operation of power systems. Starting from models already proposed, some modifications are suggested in order to adjust real plant response, recorded from different conditions and situations, to model behaviour. | URI: | http://hdl.handle.net/10261/30595 | ISSN: | 0327-0793 |
Appears in Collections: | (IRII) Artículos |
Show full item record