Título: | A highly sensitive microsystem based on nanomechanical biosensors for genomics applications |
Autor: | Lechuga, Laura M. CSIC ORCID ; Tamayo de Miguel, Francisco Javier CSIC ORCID; Álvarez, Mar CSIC ORCID; Carrascosa, Laura G. CSIC ORCID; Yúfera, Alberto CSIC ORCID; Rueda, Adoración CSIC ORCID; Plaza, José Antonio CSIC ORCID ; Zinoviev, Kirill CSIC; Domínguez-Matas, Carlos CSIC; Zaballos, Ángel; Moreno, M. CSIC; Martínez-Alonso, Carlos; Díaz, Vicente; Bernad, Antonio CSIC ORCID | Palabras clave: | Biosensors Microsystem Si technology Microcantilevers DNA biochip |
Fecha de publicación: | 25-oct-2006 | Editor: | Elsevier | Citación: | Sensors and Actuators B: Chemical 118(1-2): 2-10 (2006) | Resumen: | Microcantilever-based biosensors are a promising tool to detect biomolecular interactions in a direct way with high accuracy. We show the development of a portable biosensor microsystem able to detect nucleic acid hybridization with high sensitivity. The microsystem comprises an array of 20 micromechanical cantilevers produced in silicon technology, a polymer microfluidic system for delivery of the samples, an array of 20 vertical cavity surface emitting lasers (VCSELs) with collimated beams thanks to an integrated microlens array, an optical coupling element to provide the optical path required, and chips with the photodetectors and the CMOS circuitry for signal acquisition and conditioning, capable of measuring the cantilever deflection with sub-nanometer resolution. Robust immobilization and regeneration procedures have been implemented for the oligonucleotide receptor sequences. In a further innovation, an optical waveguide cantilever transducer has been also developed in order to improve the final performance of the device. This has a number of advantages in terms of a simple optical geometry and improved sensitivity. | Descripción: | 9 páginas, 13 figuras, 1 tabla.-- PDF pre-print.-- et al. | Versión del editor: | http://dx.doi.org/10.1016/j.snb.2006.04.017 | URI: | http://hdl.handle.net/10261/27936 | DOI: | 10.1016/j.snb.2006.04.017 | ISSN: | 0925-4005 |
Aparece en las colecciones: | (CNB) Artículos (IMN-CNM) Artículos (IMSE-CNM) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Abstract-LLechuga-Optonanogen.pdf | 238,27 kB | Adobe PDF | Visualizar/Abrir |
CORE Recommender
SCOPUSTM
Citations
68
checked on 23-mar-2024
WEB OF SCIENCETM
Citations
61
checked on 27-feb-2024
Page view(s)
428
checked on 28-mar-2024
Download(s)
216
checked on 28-mar-2024
Google ScholarTM
Check
Altmetric
Altmetric
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.