Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/266923
COMPARTIR / EXPORTAR:
logo OpenAIRE logo OpenAIRE logo DataCite BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE
logo citeas Santis, S. D. (2022, April 13). AxCaliber_3D. DIGITAL.CSIC. http://doi.org/10.20350/DIGITALCSIC/14601

Invitar a revisión por pares abierta
Título

AxCaliber_3D

AutorDe Santis, Silvia CSIC ORCID
Palabras claveDiffusion MRI
Axonal caliber
White matter
Fecha de publicación13-abr-2022
EditorDIGITAL.CSIC
CitaciónSantis, Silvia de: 2022; AxCaliber_3D [software]; DIGITAL.CSIC; https://doi.org/10.20350/digitalCSIC/14601
ResumenSoftware to analyse diffusion weighted MRI data collected with varying b-value/diffusion times to fit the AxCaliber model for white matter diffusion by Barazany et al. 2009, adapted for including different fiber orientations (De Santis et al, EMBC 2019)
URIhttp://hdl.handle.net/10261/266923
DOIhttps://doi.org/10.20350/digitalCSIC/14601
Licencia de usohttps://creativecommons.org/licenses/by-nc/4.0/
Trabajos citantesBarazany D, Basser PJ, Assaf Y. 2009. In vivo measurement of axon diameter distribution in the corpus callosum of rat brain. Brain 132:1210?1220. doi:10.1093/brain/awp042
De Santis S, Herranz E, Treaba CA, Barletta V, Mehndiratta A, Mainero C, Toschi N. 2019. Whole brain in vivo axonal diameter mapping in multiple sclerosis2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Presented at the 2019 41st Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). Berlin, Germany: IEEE. pp. 204?207. doi:10.1109/EMBC.2019.8856433
De Santis, Silvia; Jones, Derek K.; Roebroeck Alard. 2016. Including diffusion time dependence in the extra-axonal space improves in vivo estimates of axonal diameter and density in human white matter. NeuroImage 130: 91-103. doi: 10.1016/j.neuroimage.2016.01.047.
Sánchez, José A.; Mainero, Caterina; De Santis, Silvia. A translational MRI approach to validate acute axonal damage detection as an early event in multiple sclerosis. https://doi.org/10.7554/eLife.79169. http://hdl.handle.net/10261/359201
Aparece en las colecciones: (IN) Software de investigación

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
AxCaliber_3D_folder.tar.gz191,96 kBUnknownVisualizar/Abrir
readme.txt4,29 kBTextVisualizar/Abrir
Mostrar el registro completo

CORE Recommender

Page view(s)

229
checked on 20-ene-2025

Download(s)

24
checked on 20-ene-2025

Google ScholarTM

Check

Altmetric

Altmetric



Este item está licenciado bajo una Licencia Creative Commons Creative Commons