Por favor, use este identificador para citar o enlazar a este item:
http://hdl.handle.net/10261/25667
COMPARTIR / EXPORTAR:
SHARE CORE BASE | |
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE | |
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Mazuelas Esteban, Ángel José | - |
dc.contributor.author | Dotor-Castilla, María Luisa | - |
dc.contributor.author | Golmayo, Dolores | - |
dc.contributor.author | Zeimer, U. | - |
dc.contributor.author | Baumbach, T. | - |
dc.contributor.author | Luebbert, D. | - |
dc.contributor.author | Grenzer, J. | - |
dc.contributor.author | Baruchel, J. | - |
dc.date.accessioned | 2010-06-25T07:43:25Z | - |
dc.date.available | 2010-06-25T07:43:25Z | - |
dc.date.issued | 2001-05-21 | - |
dc.identifier.citation | Journal of Physics D: Applied Physics 34(10A): A117-A121 (2001) | en_US |
dc.identifier.issn | 0022-3727 | - |
dc.identifier.uri | http://hdl.handle.net/10261/25667 | - |
dc.description | 5 páginas, 8 figuras. | - |
dc.description.abstract | For the first time, we have obtained the real-time observation, by x-ray topography, of the laser degradation due to the formation of misfit dislocations. We drive the laser diode under a high-energy, high-flux synchrotron micro-x-ray beam. We simultaneously obtain both the laser characteristic curve and the structural characteristics during operation, i.e. the presence of misfit dislocations, laser diode curvature and strain status. From the strain we measure the temperature increase in the epilayer due to the injection current. In other lasers device degradation occurred without the formation of misfit dislocations, but by mass transport, and in other lasers no structural degradation was observed. | en_US |
dc.format.extent | 466409 bytes | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | en_US |
dc.publisher | Institute of Physics Publishing | en_US |
dc.rights | closedAccess | en_US |
dc.subject | Optics | en_US |
dc.subject | Quantum optics | en_US |
dc.subject | Lasers | en_US |
dc.title | Observation of dislocation generation in highly strained quantum well lasers during operation | en_US |
dc.type | artículo | en_US |
dc.identifier.doi | 10.1088/0022-3727/34/10A/324 | - |
dc.description.peerreviewed | Peer reviewed | en_US |
dc.relation.publisherversion | http://dx.doi.org/10.1088/0022-3727/34/10A/324 | en_US |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es_ES |
item.fulltext | No Fulltext | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | artículo | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
Aparece en las colecciones: | (IMN-CNM) Artículos |
CORE Recommender
NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.