Please use this identifier to cite or link to this item: http://hdl.handle.net/10261/248554
Share/Export:
logo share SHARE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE
Title

Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”

AuthorsBenedi, Clara CSIC ORCID CVN; Viñas, María CSIC ORCID; Lago, Carmen M.; Aissati, Sara CSIC; Castro, Alberto de CSIC ORCID; Dorronsoro, Carlos CSIC ORCID; Marcos, Susana CSIC ORCID
KeywordsVisual acuity
Aberrations
Magnification
Adaptive optics
Cuvette
Issue Date20-Aug-2021
PublisherDIGITAL.CSIC
CitationBenedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana; 2021; Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”; DIGITAL.CSIC; http://dx.doi.org/10.20350/digitalCSIC/13974
AbstractVisual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus).
DescriptionThe provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021).
URIhttp://hdl.handle.net/10261/248554
DOI10.20350/digitalCSIC/13974
ReferencesBenedi, Clara; Viñas, María; Lago, Carmen M.; Aissati, Sara; Castro, Alberto de; Dorronsoro, Carlos; Marcos, Susana (2021). Optical and visual quality of real intraocular lenses physically projected on the patient’s eye. Biomedical Optics Express 12(10): 6360-6374. https://doi.org/10.1364/BOE.432578 . http://hdl.handle.net/10261/250758
Appears in Collections:(CFMAC-IO) Conjuntos de datos

Files in This Item:
File Description SizeFormat
All_data_cuvette.xlsxdataset25,09 kBMicrosoft Excel XMLView/Open
readme.odt5,66 kBOpenDocument TextView/Open
Show full item record
Review this work

Page view(s)

80
checked on May 22, 2022

Download(s)

19
checked on May 22, 2022

Google ScholarTM

Check

Altmetric

Dimensions


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.