Title

The relevant role of ion mobility separation in LC-HRMS based screening strategies for contaminants of emerging concern in the aquatic environment

AuthorsCelma, Alberto; Ahrens, Lutz; Gago-Ferrero, Pablo CSIC ORCID; Hernández, Félix; López, Francisco; Lundqvist, Johan; Pitarch, Elena; Sancho, Juan Vicente; Wiberg, Karin; Bijlsma, Lubertus
KeywordsIon mobility
Screening workflow
Liquid chromatography high-resolution mass spectrometry
Collision cross section (CCS)
Environmental analysis
Issue DateOct-2021
PublisherElsevier
CitationChemosphere 280: 130799 (2021)
AbstractIon mobility separation (IMS) coupled to high resolution mass spectrometry (IMS-HRMS) is a promising technique for (non-)target/suspect analysis of micropollutants in complex matrices. IMS separates ionized compounds based on their charge, shape and size facilitating the removal of co-eluting isomeric/isobaric species. Additionally, IMS data can be translated into collision cross-section (CCS) values, which can be used to increase the identification reliability. However, IMS-HRMS for the screening of contaminants of emerging concern (CECs) have been scarcely explored. In this study, the role of IMS-HRMS for the identification of CECs in complex matrices is highlighted, with emphasis on when and with which purpose is of use. The utilization of IMS can result in much cleaner mass spectra, which considerably facilitates data interpretation and the obtaining of reliable identifications. Furthermore, the robustness of IMS measurements across matrices permits the use of CCS as an additional relevant parameter during the identification step even when reference standards are not available. Moreover, an effect on the number of true and false identifications could be demonstrated by including IMS restrictions within the identification workflow. Data shown in this work is of special interest for environmental researchers dealing with the detection of CECs with state-of-the-art IMS-HRMS instruments.
Publisher version (URL)https://doi.org/10.1016/j.chemosphere.2021.130799
URIhttp://hdl.handle.net/10261/242718
DOIhttp://dx.doi.org/10.1016/j.chemosphere.2021.130799
Appears in Collections:(IDAEA) Artículos
Files in This Item:
File Description SizeFormat 
1-s2.0-S0045653521012704-main.pdfArtículo principal3,25 MBAdobe PDFThumbnail
View/Open
1-s2.0-S0045653521012704-mmc1.pdfMaterial suplementario152,81 kBAdobe PDFThumbnail
View/Open
Show full item record
Review this work
 

Related articles:


WARNING: Items in Digital.CSIC are protected by copyright, with all rights reserved, unless otherwise indicated.