Por favor, use este identificador para citar o enlazar a este item: http://hdl.handle.net/10261/239686
COMPARTIR / EXPORTAR:
logo share SHARE logo core CORE BASE
Visualizar otros formatos: MARC | Dublin Core | RDF | ORE | MODS | METS | DIDL | DATACITE

Invitar a revisión por pares abierta
Título

Chest Implantation of Adjustable Gravitational Valves: An Easy, Safe, and Stable Alternative to Control Symptomatic Overdrainage in Shunted Children

AutorTirado Caballero, Jorge; Rivero-Garvía, Mónica; Moreno-Madueño, Gloria; Gómez-González, Emilio CSIC ORCID; Márquez-Rivas, Javier CSIC ORCID
Palabras claveGravitational valve
Hydrocephalus
Overdrainage
Ventriculoperitoneal shunt
Fecha de publicaciónfeb-2021
EditorElsevier
CitaciónWorld Neurosurgery 146: 90-94 (2021)
Resumen[Objective] Shunt overdrainage is a potential complication in pediatric hydrocephalus. The addition of adjustable gravitational units to previous shunt systems has been proposed as effective management for this problem. These devices have been traditionally implanted over the occipital bone. We propose chest implantation as an easier, safer, and more stable alternative in the pediatric population, especially in those cases with parieto-occipital shunts.
[Methods] This study comprises a retrospective analysis from a unicentric case series of pediatric patients affected by overdrainage and managed with adjustable gravitational valves implanted in the chest. The device implantation technique is described in detail and takes no more than 15 minutes.
[Results] Thirty-seven patients met the criteria. The mean age of implantation was 9.62 years. The mean follow-up in the series was 38 months. The mean number of pressure adjustments was 2.48. The mean “deviation angle” of the device to the longitudinal body axis was 5.8°. The complications per year of shunt were <0.02 with no disconnection of the catheters in any case during follow-up.
[Conclusions] In our experience, chest implantation for adjustable gravitational devices was a suitable shunt modification in pediatric patients suffering from overdrainage.
Versión del editorhttp://doi.org/10.1016/j.wneu.2020.11.001
URIhttp://hdl.handle.net/10261/239686
DOI10.1016/j.wneu.2020.11.001
Identificadoresdoi: 10.1016/j.wneu.2020.11.001
issn: 1878-8750
Aparece en las colecciones: (IBIS) Artículos




Ficheros en este ítem:
Fichero Descripción Tamaño Formato
accesoRestringido.pdf15,38 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo

CORE Recommender

SCOPUSTM   
Citations

2
checked on 08-abr-2024

WEB OF SCIENCETM
Citations

2
checked on 27-feb-2024

Page view(s)

51
checked on 18-abr-2024

Download(s)

13
checked on 18-abr-2024

Google ScholarTM

Check

Altmetric

Altmetric


NOTA: Los ítems de Digital.CSIC están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.